Author: Site Editor Publish Time: 19-10-2026 Origin: Site
The same 5.5 kW load, a continuously running conveyor line and a lifting platform that starts and stops 120 times per hour require different transmission configurations. For the former, it is enough to calculate the power according to the S1 continuous working system, while for the latter, the heat of the starting current, braking energy and the number of starts and stops per hour must be included. The root cause of many on-site reducer heating problems is not the reducer itself, but the fact that intermittent working conditions are sometimes regarded as continuous working conditions. This article breaks down an easily skipped link in matching motor power and reducer - duty cycle and duty cycle - into executable steps.
The duty cycle describes the cycle law of "time-load", the duty cycle describes the proportion of load time in a cycle, and the service factor is the mechanical and thermal power margin of the reducer based on standard working conditions. The three act on different objects: the working system and the duty cycle determine how much power and number of starts the motor allows; the service coefficient determines the mechanical load margin of the reducer gear and bearings. Treating the service coefficient as a heat dissipation margin, or using the rated power of the S1 motor to directly apply the S4 working condition, is the starting point for all subsequent questions.
There is no need for complicated testing equipment. Just write down four numbers on site and the working system is basically determined:
Loading time T1 : The actual number of seconds of running with load in a cycle, for example, the driving speed rises for 20 s;
Stop or no-load time T2 : How long is the power off between two loads, or how long is the no-load operation;
Load rate : whether the loaded section is full load, partial load or impact load, the impact peak value is several times the average value;
Start, stop and braking frequency : how many times per hour, whether there is electric braking or mechanical braking, and whether there is frequent forward and reverse rotation.
Among these four items, the number of starts per hour is often missed, but it directly determines which gear the motor should choose. The current of a direct start can reach 5 to 7 times the rated value, and the start time is 5 to 10 s. The copper consumption during this period is equivalent to tens of seconds of full load operation. The denser the start, the higher the heat.
The national standard GB 755-2019 is equivalent to IEC 60034-1 and divides the work system into S1~S10. Motors whose working system is not marked on the nameplate are treated as S1 by default - this is a conservative assumption, and it is also easy to misuse on site.
work system | cyclic features | thermal state | Typical occasions |
|---|---|---|---|
S1 continuous | Constant load long-term operation | achieve thermal stability | Fans, water pumps, continuous conveying lines |
S2 short time | After loading for a period of time, stop and cool down to ambient temperature. | Not stable | Gate opening, closing and clamping devices |
S3 discontinuous cycle | Load-stop cycle, cycle ≤10 min, starting heat can be ignored | Not stable | Light load traveling, stamping, packaging machines |
S4 with start-up stutter | Startup heat cannot be ignored based on S3 | Not stable | Frequent starting and stopping of conveyors and small lifting |
S5 includes electric braking discontinuity | Start - load - electric braking - stop | Not stable | Elevator, rapid positioning axis |
S6 continuous cycle | Alternating between loaded and unloaded, without stopping | Not stable | Rolling mills, some machine tools |
S7~S9 | Including braking, variable speed or non-cyclic loads | Converted according to equivalent load | Steel rolling, crushing, construction machinery |
The loading time of S2 is marked according to the standard gears, commonly 10, 30, and 60 minutes; the duty cycle gears of S3~S5 are commonly 15%, 25%, 40%, and 60%. Working conditions that exceed 60% and the cycle is greater than 10 minutes are actually close to S1 and should be treated as continuous working conditions Selection.
The algorithm of the duty cycle (ED%, also called load duration) is very straightforward:
ED = T1 ÷ (T1 + T2) × 100%
Convert the intermittent load into equivalent continuous load and take the root mean square according to the isothermal effect. M_eq = M × √ED is commonly used in engineering . For example, if the load section is 7.5 kW and ED is 25%, the equivalent continuous power is 7.5 × 0.5 = 3.75 kW.
Duty load rateED | √ED coefficient | 7.5 kW equivalent continuous power with load |
|---|---|---|
15% | 0.39 | 2.9kW |
25% | 0.50 | 3.75kW |
40% | 0.63 | 4.7kW |
60% | 0.77 | 5.8kW |
The converted value can only be used to determine "whether the heat is sufficient" and cannot be directly used as Selection power. There are two reasons: iron loss and mechanical loss do not decrease with the load, and the actual improvement range is compressed; the allowable output of the motor with the same frame at S3 40% is usually only 15%~30% higher than S1, which is much smaller than the theoretical value of √ED inversion. Therefore, the power table provided by working system in the manufacturer"s sample is more credible than any conversion formula.
After calculating the ED, only half of the thermal calibration is completed. Three corrections need to be made when it comes to the specific configuration:
1. Start frequency correction. The higher the number of starts and stops per hour, the larger the motor base or independent fan is required. The general rule is: within 5 times/h, the rated value can be used; between 6 and 30 times/h, increase the speed by one gear; above 30 times/h, use the S3/S4 working system motor, and check the allowable start and stop frequencies given in the sample. If the S1 motor is used to replace the S4 working condition, the winding temperature rise will occur before the mechanical parts fail.
2. Inertia ratio correction. The ratio of the load inertia converted to the motor shaft and the rotor inertia is controlled within 10 in general situations and within 5 in high-frequency start and stop. When the inertia ratio is too large, increasing the speed ratio is a direct way to reduce the converted inertia (divided by the square of the speed ratio), which is more effective than blindly enlarging the motor.
3. Reverse and braking correction. The rated power of the reducer sample is usually based on one-way operation, no more than 5 starts per hour, and no more than 2 times the rated starting torque. Bidirectional operation or frequent reversal must be multiplied by a coefficient of 0.7~1.0; in S5 working condition, the braking energy must be converted into heat and included. Mechanical braking generates friction work every time the brake is applied. When the frequency is high, the life of the friction plate expires first.
After these three corrections are completed, the service coefficient of the reducer can be based on values: 1.15~1.3 for smooth continuous working conditions; 1.4~1.6 for medium impact; 1.5~2.5 for frequent starts and stops, forward and reverse rotation, or large inertia. The coefficient value changes in the same direction as the starting frequency and cannot be judged only by the load.
If the motor is selected correctly, the reducer still needs to be calibrated separately, because the gears and bearings are rated according to the mechanical load and not the temperature rise of the motor.
Thermal power calibration. Calculated according to Pct = P2 × KT × KW × Kalt ≤ Pt , where P2 is the working machine power, KT is the ambient temperature coefficient (40 ℃ is about 1.35, 50 ℃ is about 1.65), KW is the operating cycle coefficient (ED 60% is about 0.86), and Kalt is the altitude coefficient. The allowable thermal power Pt of the sample is based on an environment of 20°C, 100% continuous operation, and an altitude of 1000 m. It must be corrected as soon as the conditions change. This is why the thermal power calibration and mechanical power calibration of the reducer must be done separately: if the mechanical power is sufficient but the thermal power is not sufficient, the oil temperature will still reach the 85 ℃ alarm line.
Peak torque calibration. The torque at the moment of load starting and impact often reaches more than 2 times the average value, and the allowable peak value of most general-purpose models is about 1.5 times the rated output torque. When calculating the output torque of the reducer , use the peak value instead of the average value to compare the limit value; when the peak value exceeds the limit, it is more effective to enlarge the machine base or install a torque-limiting hydraulic coupling than to increase the service coefficient.
Use S1 motor to replace S3/S4 working conditions, select only according to average power, and ignore startup heat accumulation;
The converted value of the duty cycle is directly regarded as the rated power, and the selected model overheats in the continuous section;
The service coefficient is determined based on the load only, not the number of starts and stops per hour and whether it is running forward or reverse;
Forget about ambient temperature and altitude correction, there is insufficient thermal power in high-temperature workshops or plateau sites in summer.
Collection items | Example | use |
|---|---|---|
Load/stop time | Load 20 s, rest 40 s | Calculate ED and customize work schedule |
Number of starts and stops per hour | 60 times/h | Fixed startup frequency correction and service factor |
Load properties | Smooth/medium impact/heavy load | Fixed working condition coefficient |
Ambient temperature and altitude | 40 ℃, altitude 800 m | Thermal power correction |
Steering and braking | Bidirectional, mechanical brake | Reverse coefficient and friction work |
After filling out this form, the working system, duty cycle, service factor and thermal power correction have all been entered, and the rest of the sample checking and verification can be done by the Selection tool.
The working system is not a check box on the Selection table. It determines how much power the motor allows and how much margin is left in the reducer. The accuracy of the matching between the motor power and the reducer depends largely on whether the three groups of numbers T1, T2 and the number of starts and stops are recorded, and then classified according to the gears of GB 755-2019. For gear reduction motor supporting projects, it is recommended to provide the working condition curve at the inquiry stage, so that the manufacturer can issue two verification results of power and thermal power according to the actual working system.
If you need to match the transmission scheme for intermittent working conditions, please contact Hangzhou Weigao Transmission : We provide cycloidal pinwheels, hard tooth surfaces, worm gears and helical gear series products. Independent fans can be configured according to S3/S4 working conditions, and lubrication and braking interfaces can be strengthened. The technical team will complete the reducer Selection and thermal power calibration for free. As a reducer manufacturer , the local factory in Hangzhou supports customization of drawings and trial assembly of prototypes. You are welcome to request reducer quotations and drawings, or contact Hangzhou reducer manufacturer customer service for reducer consultation ; you can also directly use our reducer online tool and input power, speed and duty cycle to get configuration suggestions.
Offshore Wind Vessel Gearbox Market 2027: Crane and Winch Drive Demand
Lubrication and maintenance characteristics of B series industrial gearboxes
What are the common misunderstandings in B series gearbox maintenance?
Apron Feeder Gearbox Selection: Chain Pull, Shock Load and Service Factor
How does the R series helical gear reducer perform in a strong vibration environment Selection
Pneumatic Conveying Gearbox Market 2027: Blower, Airlock and Screw Drive Demand
Pellet Mill Gearbox Selection: Ring Die Torque, Thermal Rating and VFD Restart
Is there any way to reduce the parallelism error of the reducer?
Food and Beverage Gearbox Market 2027: Renovation Demand and Mixer Sizing
Marine Deck Winch Gearbox Selection: Drum Torque, Duty Class and Holding Brake
What specific damage will reversal with load cause to the BWY27-59-4KW cycloidal pinwheel reducer?
How to avoid XLED32-841-0.37KW cycloidal pinwheel reducer with load reversal
Desalination Plant Gearbox Market 2027: SWRO Pump Drive Demand
What are the common problems with NGW42-25 planetary reducer base welding?
What kind of noise will the reducer produce if the box manufacturing accuracy is not up to standard?
Slewing Drive Solar Tracker Selection: Wind Load and Holding Torque
Which is more efficient, cycloidal pinwheel reducer or worm gear reducer?