Author: Site Editor Publish Time: 14-11-2026 Origin: Site
Passing the mechanical strength check does not mean that the oil temperature during operation is qualified. Part of the incoming power will turn into heat. This part of the heat must be calculated clearly first, and then how much can be dissipated by the box. Only when the two lines are aligned can it be considered as passing. GB/Z 22559.1-2008 "Thermal Power of Gears Part 1: Thermal Balance Calculation of Gear Devices when the Oil Pool Temperature is 95°C" (equivalent to ISO/TR 14179-1:2001) gives this idea. Let"s go through the whole process using a 15 kW two-stage helical gear reducer.
There is relative sliding between the tooth surface in the meshing and meshing sections, and the friction work is directly converted into heat, accounting for 60% to 70% of the total loss, and is the main heat source. The friction coefficient is affected by the tooth surface roughness, lubricating oil viscosity and sliding speed. When the tooth surface is rough, the viscosity is low, and the running-in is insufficient, the value will be higher.
There is rolling friction between the rolling element and the raceway. The efficiency is high but the absolute loss is not small, accounting for 15%~20%. It is related to the bearing type, preload force, load and speed. Excessive preload will significantly amplify this item.
The gear rotates in the oil pool, lifting the oil and stirring it back. This loss accounts for 5% to 10%, and increases with the peripheral speed, tooth width, oil immersion depth and oil viscosity. High-speed and wide-tooth grades should focus on this item.
The sliding friction between the oil seal lip and the shaft surface accounts for 3% to 5%. The larger the shaft diameter and the higher the rotation speed, the more obvious it is.
Loss items | Proportion of total losses | Calorific value in this example (W) | Main influencing factors |
|---|---|---|---|
gear mesh friction | 60%~70% | 232.5~271.2 | Tooth surface roughness, oil viscosity, sliding speed |
Bearing friction | 15%~20% | 58.1~77.5 | Bearing type, preload, load, speed |
Lubricating oil splashing | 5%~10% | 19.4~38.7 | Circumferential speed, tooth width, oil immersion depth, viscosity |
Seal friction | 3%~5% | 11.6~19.4 | Shaft diameter, speed, sealing type |
These four proportions are commonly used empirical intervals in engineering, and each takes an independent value. The sum of the lower limits of the intervals is about 83%, and the sum of the upper limits is about 105%. They do not constitute a strict percentage decomposition and are used to make magnitude judgments rather than accurate calculations.
According to the calculation convention of the mechanical design manual, in the absence of precise data, the single-stage gear transmission efficiency is taken as 0.987 for gear grinding and 0.985 for hobbing, and for multi-stage gear transmission, the nth power of the single-stage efficiency is taken. In this example, the first level m=3, z1=17, z2=85, b=45, β=15°, the second level m=6, z1=17, z2=68, b=70, β=15°, the total transmission ratio is 20, the output speed is 72.50 r/min, and the output torque is 1 924.8 N·m. The total efficiency of two-stage gear grinding is η=0.987²=0.974169, and the calorific value Q1=1000×(1−η)×P1=387.47 W; if gear hobbing is changed, η=0.970225, the calorific value rises to 446.62 W.
The heat dissipation is calculated according to Q2max=K·S·(θymax−t0). K is the heat transfer coefficient, generally 8.7~17.5 W/(m²·℃), 14~17.5 for good ventilation, 8.7~10.5 for poor ventilation; S is the outer surface of the box, where the flange, bottom of the box and heat sink are calculated as half of the actual area; t0 is taken as room temperature 20°C.
The allowable equilibrium temperature θymax depends on the oil load level: heavy-duty gear oil (σH≥1 100 N/mm²) is 100℃, medium-load gear oil (σH 500~1 100 N/mm²) is 80℃; the mechanical design manual gives 60~70℃ for gear transmission, and the American AGMA 6010-E88 stipulates 95℃. The higher the value, the greater the allowable temperature difference and the smaller the required heat dissipation area. In this example, the outer surface of the box is S=1.05 m².
Heat dissipation conditions | Heat transfer coefficient K | ambient temperature | Allowable equilibrium temperature | Temperature difference Δt | Maximum heat dissipation (W) | Required heat dissipation area | determination |
|---|---|---|---|---|---|---|---|
Well ventilated | 14 | 20℃ | 80℃ | 60K | 882.0 | 0.4613 m² | Adequate heat dissipation |
Poor ventilation | 8.7 | 20℃ | 80℃ | 60K | 548.1 | 0.7423 m² | Adequate heat dissipation |
Well ventilated | 14 | 40℃ | 80℃ | 40K | 588.0 | 0.6919 m² | Adequate heat dissipation |
Poor ventilation | 8.7 | 40℃ | 80℃ | 40K | 365.4 | 1.1134 m² | Insufficient cooling |
Well ventilated | 14 | 40℃ | 100℃ | 60K | 882.0 | 0.4613 m² | Adequate heat dissipation |
The same calorific value is 387.47 W. When ventilation is good, Q2max reaches 882.0 W, and the required heat dissipation area is only 0.4613 m². With poor ventilation and an ambient temperature of 40°C, Q2max is only 365.4 W, which is less than the calorific value, indicating insufficient heat dissipation. In the same working condition, changing to heavy-load oil increases θymax to 100°C, and Q2max returns to 882.0 W. The conclusion is reversed.
Put the above chain into executable order:
Defined input conditions: motor rated power, actual load rate, input speed, installation environment temperature and ventilation conditions.
Calculate the calorific value by taking the efficiency: take the single-stage efficiency according to the accuracy level and processing method, take the nth power for multi-stage efficiency, and calculate Q1.
The allowable equilibrium temperature is determined: θymax is determined according to the oil load level, and t0 is determined according to the installation environment.
Calculate K and S: determine K according to the ventilation conditions, convert half of the outer surface of the box into S, and compare Q2max and Q1.
If it does not pass, deal with it in sequence: improve ventilation, install heat sinks, add a fan to the shaft end, or switch to oil with a higher load rating.
On-site inspections can be used in reverse. The measured oil temperature is 68℃ and t0=20℃, so Δt=48 K. If K=14 is used, Q2max is 705.6 W, which is equivalent to the calorific value being 1.821 times the design value. If it is determined that the heat generation is the designed 387.47 W, the equivalent heat transfer coefficient is only 7.688 W/(m²·℃), which is lower than the manual lower limit of 8.7, indicating that poor ventilation alone cannot explain it; if the load is actually 1.2 times the rated value, the heat generation is 465.0 W, and the equivalent heat transfer coefficient is 9.225 W/(m²·℃), which falls back to 8.7~17.5 reasonable range, the problem points to Selection being too small rather than the box design.
The oil viscosity is graded according to GB/T 3141-1994 "ISO Viscosity Classification of Industrial Liquid Lubricants" (equivalent to ISO 3448:1992) based on the kinematic viscosity intermediate value at 40°C, with an allowable deviation of ±10%. GB 5903-2011 "Industrial Closed Gear Oil" lists L-CKB ordinary, L-CKC medium load, L-CKD heavy load, and L-CKE accordingly. Worm gears and other categories. When the oil is changed in the same machine, the heat dissipation area requirements also change:
Oil category | Applicable load | Allowable equilibrium temperature | Required heat dissipation area (K=14, t0=20℃) |
|---|---|---|---|
L-CKB general industrial gear oil | Light load, non-extreme pressure | 60~70℃ | 0.5535~0.6919 m² |
L-CKC medium load industrial gear oil | σH 500~1 100 N/mm², extreme pressure type | 80℃ | 0.4613 m² |
L-CKD heavy duty industrial gear oil | σH≥1 100 N/mm², extreme pressure type | 100℃ | 0.3460 m² |
When the allowable equilibrium temperature is raised from 70°C to 80°C, the required heat dissipation area is reduced to 0.833 times; when it is raised from 80°C to 100°C, the required heat dissipation area is reduced to 0.750 times. This is another layer of value of heavy-duty oil in addition to improving load-bearing capacity. The viscosity grade itself is selected according to GB 5903-2011. The kinematic viscosity range at 40°C is as follows for reference when checking the oil:
Gear oil grade | 40℃ kinematic viscosity range (mm²/s) | illustrate |
|---|---|---|
68# | 61.2~74.8 | The lowest viscosity grade |
100# | 90~110 | Lower viscosity |
150# | 135~165 | medium viscosity |
220# | 198~242 | Common brands of general reducers |
320# | 288~352 | Select when the pitch speed is low |
460# | 414~506 | Very high viscosity |
680# | 612~748 | The highest viscosity, commonly used in worm gear oil |
The accuracy of the oil temperature rise calculation depends on three things: whether the efficiency value fits the actual processing and lubrication conditions, whether the allowable equilibrium temperature matches the selected oil load level, and whether the heat transfer coefficient and heat dissipation area are based on actual installation conditions. On the other hand, under the same power, the efficiency of the worm gear reducer is only 0.8217, and the heat generation reaches 2 674.5 W, which is 6.903 times that of the helical gear scheme with hard tooth surface. Under the same conditions, the required heat dissipation area is 3.1839 m², while the helical gear scheme is only 0.4613 m². This is the reason why the thermal balance of cycloidal pinwheel reducer, worm gear reducer and hard tooth surface reducer is obviously different. When Selection, you cannot just look at whether the torque is enough.
If you need to calculate the thermal power according to actual working conditions and get a traceable Selection plan, please contact Hangzhou Weigao Transmission. We provide a full range of cycloidal pinwheel reducers, hard tooth surface reducers, worm gear reducers and gear reduction motors, and can issue a complete calibration sheet based on ambient temperature, input speed and load spectrum.
Offshore Wind Vessel Gearbox Market 2027: Crane and Winch Drive Demand
Lubrication and maintenance characteristics of B series industrial gearboxes
What are the common misunderstandings in B series gearbox maintenance?
Apron Feeder Gearbox Selection: Chain Pull, Shock Load and Service Factor
How does the R series helical gear reducer perform in a strong vibration environment Selection
Pneumatic Conveying Gearbox Market 2027: Blower, Airlock and Screw Drive Demand
Pellet Mill Gearbox Selection: Ring Die Torque, Thermal Rating and VFD Restart
Is there any way to reduce the parallelism error of the reducer?
Food and Beverage Gearbox Market 2027: Renovation Demand and Mixer Sizing
Marine Deck Winch Gearbox Selection: Drum Torque, Duty Class and Holding Brake
What specific damage will reversal with load cause to the BWY27-59-4KW cycloidal pinwheel reducer?
How to avoid XLED32-841-0.37KW cycloidal pinwheel reducer with load reversal
Desalination Plant Gearbox Market 2027: SWRO Pump Drive Demand
What are the common problems with NGW42-25 planetary reducer base welding?
What kind of noise will the reducer produce if the box manufacturing accuracy is not up to standard?
Slewing Drive Solar Tracker Selection: Wind Load and Holding Torque
Which is more efficient, cycloidal pinwheel reducer or worm gear reducer?