Author: Site Editor Publish Time: 09-11-2026 Origin: Site
A tissue machine Yankee drive gearbox turns at only 139 rpm, so running torque looks modest. Then the machine ramps to 1,600 m/min and a 48-tonne shell must be accelerated in 150 seconds. This article works the selection — load map, ramp torque, AGMA service factor, hot-journal growth and bearing life — on a 2,800 mm machine.
A 3,660 mm Yankee needs 139 rpm; a three-stage unit at i ≈ 10.6 covers it easily. The difficulty is the high inertia gearbox duty behind it. With heads and journals the rotating assembly is about 48 tonnes at a radius of gyration near 1.55 m, so I ≈ 115,000 kg·m². With the pressure roll and motor the train sits near 130,000 kg·m², costing 0.5 × 130,000 × (14.57² − 2.55²) ≈ 13.3 MJ per ramp.
Web tension does not dominate. On a creping machine the creping doctor is the largest single consumer, pressing on a 1.83 m radius with 1–2 kN/m of line load.
Load component |
Basis |
Torque (N·m) |
|---|---|---|
Web tension |
200 N/m × 2.80 m = 560 N at R = 1.83 m |
1,025 |
Creping doctor |
1.8 kN/m × 2.80 m = 5.04 kN at R = 1.83 m |
9,223 |
Cylinder bearing friction |
2 × (0.0015 × 300 kN × 0.25 m) |
225 |
Pressure roll and felt drag share |
Measured share on sectional drives |
3,000 |
Windage and seal drag |
≈ 0.5% of 350 kW at 139 rpm |
1,700 |
Steady-state total |
Sum of the above |
15,173 |
Steady torque is 15.2 kN·m, or 221 kW — well under the 400 kW nameplate. Everything above it is transient, and transients size the gearbox.
Parameter |
Value |
|---|---|
Yankee diameter / face width |
3,660 mm / 2,800 mm |
Design speed / threading speed |
1,600 m/min (139.2 rpm) / 300 m/min (26.1 rpm) |
Total train inertia |
130,000 kg·m² |
Ramp time / starts per day |
150 s / 12 |
Motor |
400 kW, 4-pole, 1,480 rpm, S1 |
n = 60·v/(π·D) = 60 × 26.7/(π × 3.66) = 139.2 rpm, so ω = 14.57 rad/s; threading speed gives 26.1 rpm. From Table 1, Tsteady = 15,173 N·m and P = 15,173 × 14.57 = 221 kW, so the motor runs at 55% load.
Δω = (139.2 − 26.1) × 2π/60 = 11.84 rad/s, so α = 11.84/150 = 0.0789 rad/s² and Tacc = 130,000 × 0.0789 = 10,261 N·m. Peak demand is 15,173 + 10,261 = 25,434 N·m at 370 kW — the reason a 400 kW frame is fitted rather than a 250 kW one.
Twelve starts a day at 1.68× steady torque is frequent-start duty, so AGMA practice points to SF = 1.5: 15,173 × 1.5 = 22,760 N·m. The peak check, 25,434/2.0 = 12,717 N·m, is lower, so the service factor gearbox requirement governs — specify 25,000 N·m rated with a 2.0 peak factor.
The output shaft never runs at ambient. Steam at 6 bar is near 158 °C and the journal, insulated by the head, sits at 80–90 °C. Take a 500 mm journal at 85 °C against 25 °C:
Diametral growth = 11.5 × 10⁻⁶ × 500 × 60 = 0.345 mm.
Axial growth over a 1,500 mm span at 75 K = 1.29 mm.
A shrink disc sized cold therefore loses preload as the journal grows, then slips under 25 kN·m — the classic Yankee failure that looks like a keyway problem. Size the friction joint on hot interference, or use a floating quill. The hollow shaft must also tolerate ≥ 1.5 mm of axial float; a located bearing pair with 0.3 mm end play is preloaded to destruction in the first warm-up. Heat also soaks the sump, so check gearbox thermal power at 75–80 °C oil.
At 25 kN·m a final wheel of 0.45 m pitch radius carries Ft = 55.6 kN, Fr = Ft·tan20°/cos12° = 20.7 kN and Fa = Ft·tan12° = 11.8 kN. On a 260 mm output bearing, C = 1,600 kN at 45 kN equivalent load, ISO 281 gives (1,600/45)^(10/3) = 1.48 × 10⁵ million revolutions — about 17.6 million hours at 139 rpm. Output bearings are never the limit.
The input shaft is: with C = 400 kN, P = 35 kN and n = 1,480 rpm, (400/35)^(10/3) = 3,362 million revolutions, so L10h = 3,362 × 10⁶/(60 × 1,480) = 37,900 hours — 6.3 years at 6,000 h/year, falling to 12,000 h if contamination lifts P to 50 kN. That bearing, not the flank, sets gearbox bearing life and the overhaul interval.
Crepe ratio is set by the speed difference between Yankee and reel, and 0.5 mm of circumferential lost motion at the shell — 0.016° — shows as basis-weight banding. Specify ISO 1328 (GB/T 10095) grade 6 for the high-speed stages and grade 7 for the final stage, carburised to 58–62 HRC with Ra ≤ 0.8 µm, and 0.10–0.20 mm total output backlash. Keep the first torsional natural frequency at least 3× the highest excitation order, or the ramp passes through it.
Item |
Limit / specification |
|---|---|
Vibration, ISO 20816-3 Group 1 (> 300 kW) |
Good ≤ 2.3 mm/s, alarm 4.5, trip 7.1 mm/s rms |
Gear unit, ISO 20816-9 |
No mesh-order peak above 2.8 mm/s |
Sump oil temperature |
≤ 80 °C continuous, alarm 85 °C, PAO ISO VG 220 |
Bearing housing |
Rise ≤ 40 K, alarm 80 °C |
Hollow shaft runout / axial float |
≤ 0.03 mm TIR / ≥ 1.5 mm |
Shrink disc slip torque |
≥ 2 × 25,000 N·m, verified hot at 85 °C |
Commission 30 minutes unloaded at threading speed, 2 hours at 50% with the doctor retracted, then ten full ramps with oil samples after the first and the tenth. If mesh-order amplitude rises more than 30% between ramp one and ramp ten, the shrink disc is slipping or alignment has moved.
Sizing on running power and ignoring the 13.3 MJ ramp — a gearbox 40% too small.
Applying the service factor to nameplate power instead of measured steady torque.
No hot-state slip check on the shrink disc — the most common gearbox troubleshooting finding on tissue lines.
Locating the output bearing axially, turning 1.29 mm of growth into preload.
A Yankee drive is bought on three numbers that never appear on a nameplate: peak ramp torque, hot-journal interference and high-speed bearing life. Get them right and a 25 kN·m unit runs a decade; get them wrong and the coupling spins on a journal that grew three-tenths of a millimetre. Our online gearbox selection system runs the ratio, thermal and gearbox sizing checks directly, and our bevel-helical and parallel-shaft ranges are built as SEW, NORD and Flender compatible replacements for tissue and paper machine drives.
Apron Feeder Gearbox Selection: Chain Pull, Shock Load and Service Factor
How does the R series helical gear reducer perform in a strong vibration environment Selection
Pneumatic Conveying Gearbox Market 2027: Blower, Airlock and Screw Drive Demand
Pellet Mill Gearbox Selection: Ring Die Torque, Thermal Rating and VFD Restart
Is there any way to reduce the parallelism error of the reducer?
Food and Beverage Gearbox Market 2027: Renovation Demand and Mixer Sizing
Marine Deck Winch Gearbox Selection: Drum Torque, Duty Class and Holding Brake
What specific damage will reversal with load cause to the BWY27-59-4KW cycloidal pinwheel reducer?
How to avoid XLED32-841-0.37KW cycloidal pinwheel reducer with load reversal
Desalination Plant Gearbox Market 2027: SWRO Pump Drive Demand
What are the common problems with NGW42-25 planetary reducer base welding?
What kind of noise will the reducer produce if the box manufacturing accuracy is not up to standard?
Slewing Drive Solar Tracker Selection: Wind Load and Holding Torque
Which is more efficient, cycloidal pinwheel reducer or worm gear reducer?
Fertilizer Plant Gearbox: Turnaround Season Demand and Sizing Guide