The composition and test method of no-load loss of asynchronous motor on FA27 reducer.When a newly purchased reducer or gear reduction motor is purchased, a no-load test is usually performed.Today, let’s take a look at what should be done during the no-load experiment. What part constitutes the loss of the FA27 reducer? Let’s see how it is tested?
The motor no-load test is a very important test in the motor type test. It refers to a test in which the motor has no effective power output at its shaft end when it is running as a no-load motor.The no-load loss is obtained from the no-load test and mainly includes iron loss and wind friction loss.
1. Test method for no-load loss of asynchronous motor
The test was conducted at the rated frequency of the gear reduction motor and with no load on the rotor shaft.Adjust the stator terminal voltage to gradually reduce the stator terminal voltage from about 1.25 rated voltage U1 until the slip rate increases significantly and the no-load current reaches the minimum.
Each time the stator phase voltage U1, no-load phase current I0 and no-load input total power P0 are measured.Then from the test data, the change curve of the motor's no-load phase current I0 and the total no-load input power P0 with the stator phase voltage U1 can be obtained, which is what we often call the no-load characteristic curve.
Asynchronous motor no-load characteristic curve
2. The composition of no-load loss
The no-load input power is the total loss of the reducer motor during no-load operation. The total loss includes stator copper loss, rotor copper loss, iron loss and wind friction loss, because no-load means the motor speed is close to the synchronous speed (slip rate is 0). Therefore, the rotor copper loss can be ignored when no load is applied.
1.Constant loss
The no-load input power of the reduction motor minus the stator copper loss at the test temperature is the constant loss (Pcon). The constant loss is equal to the sum of wind friction loss and iron loss.
P0: No-load input power (w)
I0: No-load current (A)
R0: DC resistance at no-load test temperature
2. Wind and friction consumption Pfw
The wind friction loss is only related to the speed and has nothing to do with the voltage. The no-load http://www.vemte.com operating speed is basically stable. The wind friction loss can be considered as a constant. In the no-load characteristic curve, do Pcon versus (U0/Un)2 Curve, the straight line extending to zero voltage is the wind friction loss Pfw. It can be considered that the wind friction loss has nothing to do with the load.
3. Iron consumption Pfe
Make a relationship curve between Pfe and U0/Un. Under different loads, the iron loss varies according to the voltage Ub/Un on the curve.
The rated voltage iron loss of the voltage is determined according to Ub=Un.
From the perspective of the composition and analysis of losses, the no-load characteristic curve plays a vital role in the analysis of losses.For the measurement of no-load test, the no-load test needs to test the electrical parameters of the motor at different voltage points. The voltage and current span is relatively large, and the no-load test data needs to be collected quickly.Therefore, a wide test range is particularly important.