Author: Site Editor Publish Time: 24-10-2026 Origin: Site
The most common problem The model number was written correctly, the price was negotiated, and the goods arrived. Three months after installation, it was found that the oil temperature was high, the noise exceeded the standard, and the coupling was not supplied. When I looked back at the agreement, there was only one sentence 'in line with national standards' written in it. What these types of disputes have in common is that there is no judgment value in the agreement that can be measured with an instrument.when buying a reducer is often not the price comparison, but the few pages of the technical agreement.
The essence of a technical agreement is to turn 'I thought' into 'a number signed and confirmed by both parties'. It does not need to be written as a long paper, but six types of information about the reducer must be put on paper: scope of supply, working condition parameters, reference standards and judgment values, test and witness methods, packaging and transportation, warranty and breach of contract liability. The following is an item-by-item breakdown of these six chapters, with three tables that can be directly applied.
It is recommended that the order of chapters of the agreement be fixed, and be reviewed chapter by chapter to avoid omissions. The scope of supply solves "who supplies what"; working conditions and parameters solve "what to choose"; standards and acceptance solves "how to judge qualified"; testing and witness solves "who will test and when"; packaging and transportation solves "who is responsible if it breaks on the road"; warranty and penalties solves "what happens if something goes wrong".
Among the six chapters, the two chapters that are easily skipped are the scope of supply and test testimony. The former leads to the "missing backstop" debate, and the latter leads to the "you say it"s unqualified, I say it"s qualified" deadlock. The effort of two pieces of paper can save several months of coordination later.
The parameter table is not a sample copy, but a translation of the conditions at the usage site into Selection for input. By filling out one less item, the supplier will have more room for discretion. The following table shows the twelve common fields in the reducer Selection stage, and the consequences of missing them.
Field | Fill in requirements and examples | Consequences of missing information |
|---|---|---|
Purpose and equipment | Such as "main drive of apron feeder", with a simplified diagram of working conditions attached | Select according to general working conditions, lifespan will be cut in half under impact conditions |
Motor power/speed | P=30 kW, n₁=1470 r/min, including frequency conversion range | Unable to calculate thermal power, low speed section is prone to overheating |
Output speed/speed ratio | n₂=32 r/min, i≈45.9, ±3% allowed | After the speed ratio is rounded up, the production capacity does not meet the standard. |
Load properties | Constant torque/square torque/constant power, starting frequency | The service coefficient value is too small, and the tooth surface is pitted early. |
Daily running time | 24 hours continuous/8 hours single shift/intermittent | Thermal Balance Calibration Distortion |
Service factor fs | Uniform 1.0~1.25, medium impact 1.4~1.6, heavy impact 1.75 or more | Rated torque is enough, peak torque is not enough |
Installation method and location | M1~M6, horizontal/vertical, the oil level and breather cap direction change accordingly | The oil level mirror is in the wrong position and the actual oil level is insufficient. |
Output shaft connection | Solid shaft flat key/hollow shaft expansion sleeve/spline/shrink disc | Interface does not match, on-site modification |
Radial and axial loads | Cantilever force Fr, axial force Fa and action point distance | If the bearing is selected too small, it will fail early. |
environmental conditions | Ambient temperature, altitude, dust, humidity, corrosion level | Insufficient insulation and heat dissipation margin |
Protection and cooling | IP55, natural cooling/fan/oil cooling/water cooling | Forced to operate at reduced load during high temperature season |
Lubricants and coatings | Mineral oil ISO VG220, dry film ≥100 μm | Mixed oil products, paint film and salt spray do not pass the test |
In the torque column, be sure to indicate whether it is output torque or motor side torque. Calculated according to T₂=9550×P×i×η/n₁, when 30 kW, i=45.9, η=0.96, T₂≈8600 N·m; then multiplied by the service factor 1.5, the Selection torque should be calculated as 12 900 N·m for the machine base, not 8600 N·m. If this number is written incorrectly, the entire other terms of the agreement will be meaningless.
The sentence 'in line with national standards' is not enforceable at the acceptance site, because the same indicator in the national standard is often divided into multiple levels. The correct way to write it is in three stages: reference standard number + adoption level + judgment value. The commonly used acceptance indicators and corresponding calibers of reducers are shown in the table below.
Acceptance items | Reference standards | Recommended judgment value |
|---|---|---|
Gear accuracy | GB/T 10095.1 | Industrial general grade 8, precision transmission grade 6~7 |
contact spots | GB/Z 18620.4 | Tooth height direction ≥70%, tooth length direction ≥90% (inspection under rated load) |
no-load noise | GB/T 6404.1 | 1 m away from the center plane of the cabinet, A weighting ≤ 85 dB (A), small specifications are tightened step by step according to the sample |
vibration | GB/T 6404.2 | Not lower than grade C; the effective value of the speed at the bearing seat is ≤2.8 mm/s (ordinary accuracy) |
No-load temperature rise | Product standards/agreement | Oil pool ≤ 35 K, bearing ≤ 40 K |
Load temperature rise | Product standards/agreement | The upper limit of oil temperature is 65~80 ℃, and the upper limit of bearing is 85~90 ℃ (according to the model caliber) |
Sealing | JB/T 7929 | 0.03 MPa, hold pressure for 20 s, pressure drop ≤5×10⁻⁵ MPa; no leakage on the joint surface |
cleanliness | JB/T 7929 | Class C (precision models can be upgraded to Class J) |
Transmission efficiency | JB/T 5558 | Each level of cylindrical gears is ≥98%; planetary level one is 98.5%, level two is 97%, and level three is 95.5% |
Shaft extension radial circular runout | GB/T 1184 | ≤IT9, measured by dial indicator |
coating | GB/T 9286 | Total dry film thickness ≥100 μm, adhesion level 1 |
The judgment value must be followed by a measurement condition, otherwise it will still be an empty clause: the noise measuring point is 1 m away from the box, and the background noise is more than 10 dB(A) lower than the measured value; the temperature rise is based on thermal balance, and the temperature change of each measuring point within 30 minutes is considered stable if the temperature change of each measuring point is ≤1°C; the vibration measuring points are in three directions of the bearing seat. Without writing these conditions, the same machine can produce two sets of conclusions.
Each reducer should undergo a no-load test before leaving the factory: forward and reverse operation at rated speed for no less than 1 hour (some product standards require 2 hours). During this period, noise, vibration, bearing and oil pool temperatures, and seal leakage should be recorded. After passing the no-load test, perform air tightness inspection, and then perform load test on a sampling basis or one unit at a time.
The load test is closer to reality with proportional and graded loading: no load linkage ≥4 h, 25% load ≥16 h, 50% load ≥24 h, 75% load ≥48 h, and the tooth surface and temperature rise are observed step by step. The cost of doing everything is high. In practice, the choice is based on the importance of the model. However, "which levels will be done, how long will it be done, and who will record it" should be clearly stated in the agreement.
There are three recommended ways of witnessing: document witnessing (factory inspection report, material list, dynamic balancing record), video witnessing (full video recording of no-load operation and noise measurement), and on-site witnessing (buyer or third party arriving at the factory, notified 7 days before FAT). On-site witnessing is required for key units, and document witnessing is sufficient for general models. It is not necessary to upgrade all units.
A common dispute at the scene is not the reducer itself, but "who supplies this one?" Each item in the agreement should be ticked, and no blanks should be left.
project | common attribution | Remark |
|---|---|---|
Reducer body and base | supplier | Includes nameplate, oil level mirror, breather cap, lifting lugs |
Motor and connecting flange | According to the contract, the IEC flange number must be stated | Direct connection type must indicate the motor base and flange specifications. |
Coupling, expansion sleeve, key | Usually the buyer must express | The hollow shaft expansion sleeve is usually supplied with the reducer. |
Backstop/brake | Optional as needed | Inclined conveying must be checked. Missing supply will lead to back slipping. |
Cooler, oil pump, oil pipe | Oil-cooled models are supplied with the supplier | For water cooling, please indicate the water quality and interface size. |
Anchor bolts and pads | usually buyer | Specifications and grades are given in the agreement |
First filling of lubricant | supplier | Indicate the brand number and filling amount |
random files | supplier | Instructions, certificate, packing list, general drawing |
There are two common loopholes in warranty terms: vague starting points and missing response times. The specification is "18 months from the date of acceptance of the goods, or 12 months from the date of operation, whichever comes first", and a separate line "If the installation is delayed for more than 6 months due to the buyer"s reasons, the warranty period shall be calculated from the 7th month after the arrival of the goods." This not only protects the buyer, but also prevents the supplier from bearing warehousing risks indefinitely.
It is recommended that the response terms be written in three paragraphs: a written reply within 24 hours after receiving the notification, a treatment plan within 48 hours, and arrival within 72 hours if on-site service is required (remote areas are subject to consultation). The penalty for delayed delivery is calculated at 0.5%/day, with a cumulative upper limit of 5%. If the upper limit is exceeded, the buyer has the right to terminate the contract - if the upper limit is not written, the penalty will lose its deterrent effect.
Only write the model number and not the operating conditions . The model number only describes the structure and base, but does not indicate how much impact the machine can withstand. The lifespan of the same model can differ by more than three times under uniform load and crusher operating conditions.
References to obsolete or inapplicable standards . Standards change versions frequently, so the agreement should write 'currently valid version', or directly state the version number and agree on how to deal with version changes, so as to avoid each party having a version of the standard for comparison during acceptance. Reducer product standards and noise and vibration measurement standards have been revised in recent years. You will not suffer any loss if you verify them before signing.
Missing interface division . Once the 'small items' such as couplings, anchor bolts, and cooling water connections are not clearly written down, work will be stopped on site. Table ticks are more reliable than textual descriptions.
A good reducer technical agreement reads like a checklist: each item has a numerical value, a standard number, a measurement method, and a responsible party. It does not increase the procurement cost, but just prices in advance any disputes that may occur later. After writing the first draft, it is recommended to do a self-examination - hand the agreement to a colleague who was not involved and ask him to answer 'where is this machine installed, how much torque it can carry, and how to judge whether it is qualified' using only words. Any areas that cannot be answered are the areas that need to be filled in.
Hangzhou Weigao Transmission can provide Selection accounting and agreement parameter filling support for hard tooth surface reducers , cycloidal pinwheel reducers, worm gear reducers and gear reduction motors, covering M1~M6 installation positions, service coefficient values and thermal power verification, and can compare and replace installation dimensions and torque levels according to SEW, NORD and other brand models. As a reducer manufacturer , we can provide working condition review, drawing confirmation and factory inspection records according to the project; if you need free Selection accounting or agreement template, please contact us and send us the working condition parameters to get a verifiable Selection suggestion.
Offshore Wind Vessel Gearbox Market 2027: Crane and Winch Drive Demand
Lubrication and maintenance characteristics of B series industrial gearboxes
What are the common misunderstandings in B series gearbox maintenance?
Apron Feeder Gearbox Selection: Chain Pull, Shock Load and Service Factor
How does the R series helical gear reducer perform in a strong vibration environment Selection
Pneumatic Conveying Gearbox Market 2027: Blower, Airlock and Screw Drive Demand
Pellet Mill Gearbox Selection: Ring Die Torque, Thermal Rating and VFD Restart
Is there any way to reduce the parallelism error of the reducer?
Food and Beverage Gearbox Market 2027: Renovation Demand and Mixer Sizing
Marine Deck Winch Gearbox Selection: Drum Torque, Duty Class and Holding Brake
What specific damage will reversal with load cause to the BWY27-59-4KW cycloidal pinwheel reducer?
How to avoid XLED32-841-0.37KW cycloidal pinwheel reducer with load reversal
Desalination Plant Gearbox Market 2027: SWRO Pump Drive Demand