Author: Site Editor Publish Time: 25-10-2026 Origin: Site
The gear reduction motor is an integrated assembly of the motor and the reducer. No matter how accurate the mechanical side is, it will be scrapped within a few minutes if the electrical connection is wrong. On-site wiring faults are concentrated in three places: the mismatch between voltage and connection method leads to winding overvoltage, reverse phase sequence leads to load reversal damage, and power is transmitted without testing the insulation, causing breakdown of damp windings.
Two voltages written on the nameplate (such as 230/400V) indicate that the winding can be used in two ways of connection: when the grid voltage is equal to the lower value, it is connected to delta, and when it is equal to the higher value, it is connected to star. Each phase winding of the star can only bear 1/√3 of the line voltage, and the triangle can bear the entire line voltage. If the winding is reversely connected once, the voltage of the winding will increase by 1.73 times.
Nameplate voltage | Grid line voltage | Correct connection | Voltage per phase winding |
|---|---|---|---|
230/400V | 230V | triangle Δ | 230V |
230/400V | 400V | Star Y | 231V |
400/690V | 400V | triangle Δ | 400V |
Only marked 400V | 400V | Star Y (according to wiring diagram) | 231V |
Inside the junction box are the six terminals of the three-phase winding. In the star shape, connect W2, U2, and V2 with shorting strips to form a neutral point, and connect U1, V1, and W1 to L1, L2, and L3 respectively; in the triangle, connect W2-U1, U2-V1, and V2-W1 to form a closed loop, and connect the power supply to three jumper points. The horizontal and vertical arrangement of terminals varies from manufacturer to manufacturer. Always refer to the wiring diagram on the inside of the junction box cover . When distributing a star-delta starter cabinet, all short-circuit links must be removed. It is only allowed to be used if the nameplate delta voltage is equal to the grid voltage.
When L1, L2, and L3 are connected to U1, V1, and W1 in sequence, the motors of most manufacturers are clockwise when viewed from the shaft extension end. When reversal is needed , just swap two phase wires at will. Changing three wires at the same time means no replacement. The correct sequence is to jog without load for 1~2 seconds, confirm the direction from the windshield arrow or output shaft mark, and then run online. When the pump, screw conveyor, and bucket elevator are reversed, no liquid will be discharged or material will be loaded, and the backstop will slip, which may cause material blockage and damage in a short period of time. The steering parameters can be changed with variable frequency power supply, but they still need to be reviewed on the machine side after modification.
Measurement items | meter | criterion |
|---|---|---|
Winding to ground, cold (on site) | 500V megger | ≥1 MΩ |
Winding to ground, hot | 500V megger | ≥0.5 MΩ |
Winding to ground, factory cold | 500V megger | ≥100 MΩ |
Absorption ratio R60/R15 | 500V megger | ≥1.3 |
Before measurement, cut off the power, conduct a power test, discharge the winding for about 1 minute, and disassemble all external wiring : when the loop is formed through the brake coil or the inverter, the reading will be distorted, and hitting the output side of the inverter directly with a megohmmeter will also break down the module. Units that have been stored for more than half a year or have a humidity higher than 80% for a long time must be tested; if the insulation is low, it should be dried (80~90℃) and retested before powering on.
The brake of the electromagnetic brake motor is released by the DC coil, and the DC is provided by the rectifier block in the junction box. Take the YEJ series as an example: 3kW and below are in star shape, AC 220V is taken, and the rectified DC voltage is approximately 99V; 4kW and above are in delta shape, and AC 380V is taken, and the rectified DC voltage is approximately 170V. The half-wave rectified output is about 0.45 times the input effective value, and the full-wave bridge type is about 0.9 times. Measure the coil resistance before powering on. The typical value of a 99V coil is 120~180Ω. If it is close to zero, it means a short circuit, and if it is infinite, it means a disconnection. When the output of the rectifier block is lower than 85% of the rated value, it cannot be opened, which will cause the brake to drag and the coil to become hot.
One thing that is often overlooked: the brake power supply cannot be taken from the output side of the frequency converter . During low-frequency output, the voltage drops according to the V/f curve, the brake cannot be opened, and the friction plate continues to drag. Power should be taken from the input end of the inverter. The counter electromotive force can reach hundreds of volts when the coil is powered off, and a freewheeling diode or varistor needs to be connected in parallel.
Calculate according to ΔU = √3 × I × L × R0 / 1000. Taking 30kW, 57.6A, 16mm² copper core, 100m as an example, R0 is about 1.15mΩ/m, and the voltage drop is about 11.5V, accounting for 3.0% of 380V, which is already at the critical value; heavy load and frequent starting situations should be reduced to 2%. There are three other points for variable frequency drive: the output cable should be controlled within 100m and use a symmetrical three-core shielded cable, and the shielding layer is single-ended grounded on the inverter side; for 400V systems, choose 1.0/1.1kV cable, the peak value of PWM reflected wave can reach 1100V; if it exceeds 100m, install a dv/dt or sine wave filter.
Wiring is only a part of the operation of the gear reducer motor . Together with the installation method of the reducer , the alignment accuracy, and the matching of the motor power and the reducer , it determines the life of the entire machine. It is recommended that the direction confirmation and insulation data be included in the equipment file to facilitate future investigation of the cause of reducer heating .
Hangzhou Weigao Transmission provides a series of reducers and gear reduction motors with hard tooth surfaces, cycloid pinwheels, worm gears, and other series. Wiring diagrams and debugging points are included with the machine. The power, speed ratio, and braking configuration can be calculated for free according to working conditions. As a reducer manufacturer, we support drawing confirmation and batch delivery; if you need reducer Selection consultation or wiring questions, please contact the technical team.
Offshore Wind Vessel Gearbox Market 2027: Crane and Winch Drive Demand
Lubrication and maintenance characteristics of B series industrial gearboxes
What are the common misunderstandings in B series gearbox maintenance?
Apron Feeder Gearbox Selection: Chain Pull, Shock Load and Service Factor
How does the R series helical gear reducer perform in a strong vibration environment Selection
Pneumatic Conveying Gearbox Market 2027: Blower, Airlock and Screw Drive Demand
Pellet Mill Gearbox Selection: Ring Die Torque, Thermal Rating and VFD Restart
Is there any way to reduce the parallelism error of the reducer?
Food and Beverage Gearbox Market 2027: Renovation Demand and Mixer Sizing
Marine Deck Winch Gearbox Selection: Drum Torque, Duty Class and Holding Brake
What specific damage will reversal with load cause to the BWY27-59-4KW cycloidal pinwheel reducer?
How to avoid XLED32-841-0.37KW cycloidal pinwheel reducer with load reversal
Desalination Plant Gearbox Market 2027: SWRO Pump Drive Demand
What are the common problems with NGW42-25 planetary reducer base welding?
What kind of noise will the reducer produce if the box manufacturing accuracy is not up to standard?
Slewing Drive Solar Tracker Selection: Wind Load and Holding Torque
Which is more efficient, cycloidal pinwheel reducer or worm gear reducer?