Author: Site Editor Publish Time: 20-10-2026 Origin: Site
Selection When using the reducer torque calculation formula correctly , it is more effective than memorizing the model number table. Power, torque and speed satisfy P = T·n/9550 (P is kW, T is N·m, n is r/min). From this, three basic formulas are obtained: motor terminal T₁ = 9550·P/n₁; output terminal T₂ = 9550·P·i·η/n₁; rotation speed n₂ = n₁/i. In the formula, i is the speed ratio, and eta is the transmission efficiency of the reducer.。
Example: The rated speed of a 5.5 kW motor is 1440 r/min, equipped with a hard-tooth surface reducer with i=25, and the efficiency is 0.94. Then T₁ = 9550×5.5÷1440 ≈ 36.5 N·m, T₂ = 36.5×25×0.94 ≈ 857 N·m, n₂ ≈ 58 r/min. These three numbers are the basis for checking the rated torque, thermal power and installation dimensions of the sample, and are also the common practice for calculating the output torque of the reducer .
More often, the equipment resistance is known rather than the motor power. In this case, the load torque is calculated first and then reversed. Rotating load T = F×r (F is the tangential force N, r is the radius of action m); horizontal transportation adopts F = μ·m·g acceleration component, and inclined transportation is superimposed with m·g·sinα.
Example: The conveying mass of the belt conveyor is 2000 kg, the comprehensive friction coefficient is 0.15, and the diameter of the transmission roller is 500 mm. F = 0.15×2000×9.8 ≈ 2940 N, T = 2940×0.25 ≈ 735 N·m; when the output speed is set to 60 r/min, the required power P = T·n/9550 ≈ 4.6 kW, divided by the efficiency 0.94, the shaft power is about 4.9 kW, take 5.5 kW upward. After calculating in this way, the motor power and the reducer will be matched so that 'the motor is big enough and the reducer is not enough'.
Acceleration torque T = J×α, J is the total moment of inertia converted to the axis (kg·m²), α is the angular acceleration (rad/s²), α = 2π·Δn/(60·t). The load inertia is converted to the motor shaft according to J_motor = J_load/i² and is reduced by 100 times when the speed ratio is 10.
The converted inertia ratio (load converted inertia ÷ motor rotor inertia) is recommended to be controlled within 3:1, and should not exceed 10:1 in general automation situations. The acceleration time is reduced from 1 s to 0.2 s, and the required acceleration torque increases proportionally to about 5 times. Therefore, the design torque should be taken as the peak value of "steady state + acceleration" and then compared with the allowable torque at this speed.
model | Common speed ratio range | Efficiency reference value |
|---|---|---|
Hardened cylindrical gear | Single level 3~8, two levels 8~50 | 0.96~0.97 (single level)/0.94~0.96 (multiple levels) |
Cycloidal pinwheel | Single level 9~87, two levels 121~5133 | 0.90~0.94 (single level)/0.85~0.90 (two levels) |
Worm gear | 0.80~0.90 when i≤10; 0.65~0.80 when i=20~40; 0.50~0.65 when i>60 | Decrease quickly as speed ratio increases |
planet | Single level 3~10, multi-level up to 1000 | 0.94~0.97 |
The consequences of undercalculating the efficiency are very direct: if a worm gear reducer with i=60 is estimated based on eta=0.9, the output torque will be overestimated by nearly 40%, and it will not actually be driven and will be accompanied by severe heat; if the efficiency of the cycloidal pinwheel reducer is uniformly applied at 0.95, it will be easy to select a smaller gear for the machine base and run on the edge of overload for a long time.
The rated torque only corresponds to stable and continuous working conditions. The starting torque of a directly started asynchronous motor can reach 2~2.5 times the rated value. General-purpose inverters generally provide 150% short-term overload, and jammed loads can instantly reach more than 2 times the steady state. Therefore, the design torque = calculated output torque × reducer service factor : uniform load 1.0~1.25, medium impact 1.25~1.5, heavy load impact 1.5~2.0, and check that the peak value does not exceed 80% of the instantaneous torque marked on the sample.
When you suspect that Selection is too small or want to confirm the actual load factor, measure both ends according to the on-site method of GB/T 34867.1-2017: use a torque tachometer at the output end, P₂ = T·n/9549; use a power analyzer at the input end to read the three-phase active power P₁, and the efficiency η = P₂/P₁.
method | Applicable load range | Instrument accuracy | Attention on site |
|---|---|---|---|
Torque-speed method | Full load range | Torque 0.5%, speed ±1 r/min | The sensor is connected in series to the shaft system, and the difference in coaxiality will cause the reading to jump. |
Current-power method | 75%~100% load | Electrical power meter 0.5%, CT 0.2% | The power factor is low at light load and the error is amplified |
nameplate method | 50%~100% load | — | It is only a rough estimate and cannot be used for acceptance. |
When measuring, run continuously for more than 1 hour until the oil temperature is stable, take the average value of 5 to 10 minutes and eliminate the start and stop surges; it is normal for the no-load power to be about 10% to 30% of the rated value. If it is close to the rated value, check the jamming and assembly interference. When the measured efficiency is lower than the conventional value of the same model, it is mostly due to poor lubrication or tooth surface wear, which can be judged by combining the abnormal noise and temperature rise of the reducer .
1. Substitute the output speed into T = 9550·P/n, and the calculated torque is several times larger; 2. Forget to multiply the efficiency, and the worm gear model deviates by more than half; 3. Write the 4-pole motor speed as 1500 r/min, and the actual rating is mostly 1440~1470 r/min; 4. Mix the units, 1 kgf·m ≈ 9.8 N·m, and the sample is marked in kgf·m directly as N·m If you use it, you will choose a smaller gear.
It is only half of Selection to run through the reducer torque calculation formula . Next, you must use the reducer speed ratio calculation to confirm that the output speed falls within the process window, use thermal power verification to confirm that continuous operation does not overheat, and check the installation method and output shaft connection form. If you have specific working conditions - motor power, output speed, load type, daily operating hours and starting frequency, please contact Hangzhou Weigao Transmission . We provide a complete product line of cycloidal pinwheel reducers, hard tooth surface gear reducers, worm gear reducers, planetary reducers and gear reduction motors. As a reducer manufacturer , we can provide free Selection plans and reducer quotations based on parameters , and you can also send nameplate photos for comparison with imported brands and models.
Offshore Wind Vessel Gearbox Market 2027: Crane and Winch Drive Demand
Lubrication and maintenance characteristics of B series industrial gearboxes
What are the common misunderstandings in B series gearbox maintenance?
Apron Feeder Gearbox Selection: Chain Pull, Shock Load and Service Factor
How does the R series helical gear reducer perform in a strong vibration environment Selection
Pneumatic Conveying Gearbox Market 2027: Blower, Airlock and Screw Drive Demand
Pellet Mill Gearbox Selection: Ring Die Torque, Thermal Rating and VFD Restart
Is there any way to reduce the parallelism error of the reducer?
Food and Beverage Gearbox Market 2027: Renovation Demand and Mixer Sizing
Marine Deck Winch Gearbox Selection: Drum Torque, Duty Class and Holding Brake
What specific damage will reversal with load cause to the BWY27-59-4KW cycloidal pinwheel reducer?
How to avoid XLED32-841-0.37KW cycloidal pinwheel reducer with load reversal
Desalination Plant Gearbox Market 2027: SWRO Pump Drive Demand
What are the common problems with NGW42-25 planetary reducer base welding?
What kind of noise will the reducer produce if the box manufacturing accuracy is not up to standard?
Slewing Drive Solar Tracker Selection: Wind Load and Holding Torque
Which is more efficient, cycloidal pinwheel reducer or worm gear reducer?