Author: Site Editor Publish Time: 23-10-2026 Origin: Site
Machine maintenance and preparation, seasonal production lines, and intermittent shutdowns for orders all inevitably cause the reducer to be stopped for several months. The experience of many equipment managers is that if the equipment is not broken during operation, it will cause problems after being shut down for half a year and then restarted. The three hidden dangers of corrosion, lubrication failure, and seal aging are all formed during shutdown and storage. during shutdown The maintenance and operation maintenance of the reducer are two sets of logic: during operation, the focus is on temperature, oil quality and vibration, and during storage, the focus is on moisture prevention, rust prevention and oil film maintenance. The following points will be explained clearly according to the three stages: before shutdown, during storage and restart.
First, clean the surface of oil and dust, check the box for cracks and leakage points, and avoid corrosive media remaining on the surface. Second, drain the old oil and add new oil to the upper limit of the calibrated oil level: the old oil has absorbed moisture and oxidized during operation. After standing for a long time, the oil will settle to the bottom of the box, and the gears and bearings will be separated from the oil film protection. For humid working conditions, reducer lubricating oil models containing anti-rust and anti-emulsification additives can be selected . Third, anti-rust the inner cavity: Spray anti-rust oil on metal surfaces such as gears and bearings, and large machines can release gas-phase anti-rust agents into the box. Fourth, the exposed processed surfaces such as shaft extensions and flanges should be coated with lithium-based anti-rust grease and wrapped with anti-rust film to prevent the sealing lip from drying out. If this step is not done, when restarted the cause of oil leakage in the reducer often starts with the aging oil seal.
The environmental requirements for inventory and on-site storage can be summarized into four: temperature control at -20°C ~ +40°C, avoid direct sunlight and condensation; relative humidity should not be higher than 60%~65%, keep away from acid and alkali gases and dust; the bottom of the whole machine should be raised by more than 50mm to isolate ground moisture, and it is not allowed to fall directly to the ground, nor is it allowed to be stacked and weighed; the shaft surface and the flange mating surface are strictly prohibited from being exposed and bumped. For units with couplings and pulleys, it is recommended to remove the transmission parts and store them separately, or at least loosen the coupling to eliminate the one-way static load on the output bearing - the bearings are static and compressed for a long time, and the raceways will produce indentations, which is a common source of The storage ledger must record the shutdown date, environment and each turning time. If it exceeds 12 months, it is considered an overdue seal, and the inspection level must be raised by one level before reactivation.abnormal noise in the reducer when it is restarted.
Downtime | Turning requirements | Oil products and sealing treatment |
|---|---|---|
Within 1 month | Rotate the output shaft 1 to 2 times a week to allow the oil film to re-cover on the meshing surface. | Just confirm the oil level; seal the respirator to prevent "breathing effect" from absorbing moisture. |
1~6 months | Turn the car 2 to 3 times every 1 to 2 months, and it will feel smooth and without stagnation; if possible, run without load for 5 to 10 minutes to drive away moisture every month | Check the oil level settlement; apply anti-rust grease on the shaft extension |
6~12 months | Turn the car monthly and record the changes in feel | Replace the gear oil with a new one before re-activating it; the oil left standing will easily absorb water and emulsify. |
Over 12 months | Monthly cranking, it is recommended to open an observation hole or endoscope to review the tooth surface and bearings before use. | Change the oil and flush the oil circuit; check whether the oil seal and O-ring are aged and cracked |
Two execution details: Only use manual cranking, and it is strictly forbidden to turn the car with power. Each rotation should be even and without any impact. Stop and check immediately if it gets stuck. In places where the temperature difference is large and condensation is easy, a low-temperature heating tape can be attached to the oil pan to keep the oil temperature 5~10℃ higher than the environment to eliminate condensation from the source. Worm gear models should also pay attention to the creep tendency of the worm gear material. The meshing clearance needs to be rechecked after long-term resting to prevent the hidden development of worm gear wear and pitting during downtime.
Follow five steps before putting it back into use: Take a look at the appearance. If the rust spots are slight, you can polish them with fine sandpaper and then add anti-rust oil. If the seals are cracked, they must be replaced. The second-turn car must be powered on only if it rotates smoothly and without any jamming. If the rotation is heavy, dismantle it and inspect it to rule out bearing jamming or gear corrosion. Don’t leave anything to chance. Fortunately, it is a hard start; the third electrical check, the measured insulation resistance of the unit with the motor should be no less than 1MΩ, and the damp winding needs to be dried; the fourth check is the tightening and alignment, the foundation and flange bolts are retightened, and the coupling is re-aligned; the five-step test run - no-load low-speed operation for 10 to 15 Minutes, monitor vibration, noise and temperature rise. The temperature rise ΔT does not exceed 40℃, and then load in stages according to 20%, 50% and 80% of the rated load, each stage for 30 minutes. If signs of pitting corrosion on the tooth surface or abnormal bearing clearance are found, promptly arrange for the reducer bearings to be replaced or sent for repair, and do not go online while sick. It is recommended that the disassembly, inspection and appraisal of the extended storage unit be left to experienced reducer maintenance personnel.
The first is "just keep the oil": sealing old oil is the most error-prone part in shutdown maintenance. Old oil that absorbs moisture and oxidizes will basically lose its protective effect after being parked for more than 6 months. The cost of changing the oil is much lower than the cost of a set of rusted gears. The second is "the more frequent the cranking, the better": cranking that is allowed by frequent power supply will start by mistake. Manual cranking is the standard method. The focus is to change the stress point of the bearing raceway and redistribute oil, rather than turning too much.
The core of shutdown maintenance is a four-step closed loop of "cleaning-protection-monitoring-verification": oil change and rust prevention before shutdown, periodic cranking to drive away moisture during storage, and item-by-item acceptance according to the list before restarting. Establish a storage ledger to record every cranking and oil level check, and add one more disassembly and inspection before the expired unit is put into use, so that the standby unit can truly stand up to the challenge.
Hangzhou Weigao Transmission Machinery Co., Ltd. provides cycloidal pinwheel reducers, hard tooth surface reducers, worm gear reducers, planetary reducers and gear reduction motors. All of them are rust-proof sealed and protected in packaging according to warehousing specifications before leaving the factory, and storage and first-time maintenance instructions are provided with the box. As a reducer manufacturer , whether it is for new production line preparation, imported model replacement, or overdue inventory unit start-up appraisal, we provide free Selection and technical evaluation: provide power, speed ratio, installation space and working conditions, and you can get model recommendations. If you need reducer Selection consultation or machine inventory plan, please contact Hangzhou reducer manufacturer - Hangzhou Weigao Transmission, which supports customization with drawings and samples.
Offshore Wind Vessel Gearbox Market 2027: Crane and Winch Drive Demand
Lubrication and maintenance characteristics of B series industrial gearboxes
What are the common misunderstandings in B series gearbox maintenance?
Apron Feeder Gearbox Selection: Chain Pull, Shock Load and Service Factor
How does the R series helical gear reducer perform in a strong vibration environment Selection
Pneumatic Conveying Gearbox Market 2027: Blower, Airlock and Screw Drive Demand
Pellet Mill Gearbox Selection: Ring Die Torque, Thermal Rating and VFD Restart
Is there any way to reduce the parallelism error of the reducer?
Food and Beverage Gearbox Market 2027: Renovation Demand and Mixer Sizing
Marine Deck Winch Gearbox Selection: Drum Torque, Duty Class and Holding Brake
What specific damage will reversal with load cause to the BWY27-59-4KW cycloidal pinwheel reducer?
How to avoid XLED32-841-0.37KW cycloidal pinwheel reducer with load reversal
Desalination Plant Gearbox Market 2027: SWRO Pump Drive Demand
What are the common problems with NGW42-25 planetary reducer base welding?
What kind of noise will the reducer produce if the box manufacturing accuracy is not up to standard?
Slewing Drive Solar Tracker Selection: Wind Load and Holding Torque
Which is more efficient, cycloidal pinwheel reducer or worm gear reducer?