If the torque is selected according to the steady-state value, why is the reducer still geared?

There is a typical type of fault in the on-site feedback: after the equipment has been running for half a year to a year, gear pitting, tooth root cracks, and severe direct shaft breakage can be checked back in the Selection book. The rated torque is clearly greater than the load torque. The problem is probably not the rating, but the peak torque . When the asynchronous motor is started directly, the locked-rotor torque is about 1.5 to 2.0 times the rated torque. In locked-rotor conditions such as material jamming in the conveyor and foreign matter entering the crusher, the instantaneous torque of the output shaft can reach 2.5 to 3 times the steady-state value. These peaks only last for a few tenths of a second, but are enough to leave plastic indentations on the tooth surface, which can lead to pitting corrosion and broken teeth if repeated.

Therefore, when making a reducer , overload protection should not be regarded as an accessory that is added after the equipment arrives. It is a chain that must be arranged from the design stage: first calculate the peak torque, then use a mechanical torque limiting device to cut off the impact, use electrical protection to protect the continuous overload, and finally detect the damage that has occurred through operation monitoring. Each of the four lines of defense manages a section, and the lack of one section will manifest itself in other links.

Calculate the peak torque first, then you can set a benchmark for protection.

The steady-state torque is calculated using the reducer torque calculation formula T = 9550 × P ÷ n, converted to the output shaft and then multiplied by the speed ratio and efficiency: T₂ = T₁ × i × η. This step only addresses 'how much torque is required for normal operation'. Next, the peak value must be estimated separately. The peak value usually comes from three places: motor stall torque at the moment of starting, mechanical resistance when materials are jammed or stalled, and inertial impact during forward and reverse rotation and braking. The greater the inertia and the more frequent starts and stops, the higher the proportion of the third item.

Working condition type

Typical equipment

Peak/steady state multiple

Protection settings reference

Smooth load

Centrifugal fan, water pump, horizontal belt conveyor

1.2~1.4

Set the limit at 1.3 times the rated output torque

medium impact

Mixers, packaging machines, ordinary elevators

1.5~1.8

Set the limit at 1.5~1.6 times, leaving a starting margin

Strong impact and heavy load start

Crusher, bucket elevator, scraper, rotary kiln

1.8~2.5

Set the limit at 1.8 to 2.0 times, and calculate the inertia ratio

This should be distinguished from the service factor of the reducer . The service factor multiplied by the steady-state torque results in Selection torque, which buys the fatigue life margin of the gears and bearings; the setting value of the protection device is the 'upper limit of allowable passing torque', which are not the same thing. Treating the service coefficient as a protection threshold is equivalent to allowing the reducer to run on the edge of its life margin for a long time; conversely, if the protection value is stuck according to the rated torque, it will frequently jump and stop during normal startup.

Mechanical side torque limit: How to determine the slip value of the torque limiter

The torque limiter (also called safety coupling, safety clutch) is installed between the motor and the input end of the reducer, or between the output end of the reducer and the load. When the torque exceeds the set value, it slips or disengages, cutting off the impact on the transmission chain. The differences between the three types of structures are very real:

Type

Disengagement method

Torque accuracy

reset

Applicable occasions

friction type

The friction plate slips and there is still residual torque

Generally, about ±10%

Automatically recovers after overload disappears

Conveyors, packaging lines, frequent light overloads

steel ball type

The steel ball is offside and can be equipped with a proximity switch signal

High, can be set repeatedly

Fixed-point reset requires manual or low-speed alignment

Servo, precision transmission, occasions requiring interlocking shutdown

Pin type (safety pin)

The pin is sheared and the transmission is completely disconnected

Determined by pin material and diameter

Replace pin

Mining, heavy-duty, and one-time protection are preferred

There are two calibers for setting the slip torque: when the load condition is clear, it is set according to the design strength of the equipment or the torque; when the load is unknown, it is set according to 1.2 to 2.0 times the rated torque of the connected motor, and the upper limit is used for greater impact. What is installed at the input end is to protect the reducer itself. Installing it at the output end can better reflect the real resistance of the load. However, when slipping, the reducer is still idling and needs to cooperate with the stop signal. Another point that is often overlooked is that every time the friction limiter slips, it consumes friction plates. Long-term slipping will anneal the friction surface, and the set torque will drift accordingly. On the surface, it seems to be still working, but in fact it has lost its protective ability. This type of piece is a regular consumable in the reducer accessories and must be included in the inspection.

Hydraulic coupling: soft start and torque limiting for large inertia and heavy loads

For large-inertia equipment such as belt conveyors, crushers, and mills, the impact of direct startup affects both the power grid and the gears. The torque-limiting hydraulic coupling uses the oil between the pump wheel and the turbine to transmit torque. There is no mechanical connection between the input and output. The starting process is stretched into two steps: the motor first accelerates near no-load, and then the load is slowly brought up by the oil. The starting time is usually between 10 seconds and 2 minutes, and the model with an extended rear auxiliary cavity can achieve 22 to 30 seconds. Its overload protection relies on two factors: first, the pump impeller torque stops rising after reaching the torque limit point, and the output speed drops until it stops; second, when the temperature rises to about 125°C, the fusible plug melts and the working fluid spurts out, completely cutting off the transmission.

SelectionLook at three coefficients: the starting overload coefficient is generally 1.35~1.8, the braking overload coefficient is 2.0~2.5, and the transmission efficiency is not less than 0.96. The long-distance driven by multiple motors conveyor reducer can also automatically balance the load of each driving point by using slip, which is something that rigid couplings cannot do. The oil filling amount should be adjusted according to the sample range: if there is too much oil, the torque limit point will be high and the protection will be sluggish; if there is too little oil, the slip will generate heat; the direction of the fusible plug's injection port should avoid people and cables.

Electrical side pocket: thermal relay and inverter torque limit

The strength of electrical protection is continuous overload and blocked heat, while the weakness is instantaneous mechanical impact. The thermal relay is set to 1.1 to 1.2 times the rated current of the motor, and the action time ranges from seconds to tens of seconds. It protects the windings from burning, but cannot protect the peak value of a few tenths of a second on the tooth surface. The inverter can be made more detailed: the default torque limit parameters are mostly 150%, and can be set to 150% to 200% for transportation and lifting. The overload capacity of heavy-duty inverters is usually 150% for 60 seconds; the current limit is generally set to 120% to 180% of the rating, and the filtering time is 0.05 to 0.2 seconds to avoid false triggering due to instantaneous fluctuations. If the torque limit is too high, it means there is no protection; if it is too low, the speed will be limited frequently and the motor will generate heat at low speed and high current.

How the four lines of defense cooperate: response time determines division of labor

line of defense

Typical device

response time

Main objects of protection

reset mode

Design review

Service factor, peak torque calculation

design stage

Overall machine life

—

mechanical disengagement

Torque limiter, safety pin

millisecond level

Reducer gears, shafting, downstream equipment

Automatic or replacement pin

Flexible moment limit

Torque limiting hydraulic coupling

0.1~1 second

Motor, reducer, load

Fill the fusible plug after replacing it

electrical protection

Thermal relay, frequency converter electronic overload

Seconds to minutes

Motor windings, frequency converters

manual or automatic

The reasonable sequence is to give in step by step from fast to slow: the impact is first eaten up by mechanical parts, continued overload is then cut off by electrical parts. If only electrical protection is used to block jammed materials, the reducer will often be damaged before the circuit breaker operates; if only mechanical protection is installed without electrical protection, the motor will still be stalled after slipping or shearing the pin, and the winding will still be burned.

Three easy pitfalls

First, the protection value is stuck according to the rated value. The rated torque is the continuous operation capability, not the instantaneous upper limit that is allowed to pass. If the set value is close to the rated value, it will malfunction during normal startup. Therefore, the protection is increased or even short-circuited on site, which is equivalent to giving up completely.

The second is to ignore the inertia ratio. When the ratio of load inertia to motor inertia exceeds 10, the impact torque during starting and reversing will be significantly amplified. At this time, it is not enough to set protection based on the torque multiple. It is necessary to increase the reduction ratio, install a braking unit, or use a hydraulic coupling soft start.

The third is not to reset and check after slipping. After the friction limiter slips several times, the operator often restarts it directly and continues to work. The friction plate wears thinner and thinner, and the set torque becomes lower and lower. When it is really stuck, it can no longer carry the load, and the fault changes from 'protection action' to 'insufficient output'. The correct approach is to record every slip and arrange maintenance and inspection of the reducer according to the cumulative number of slips .

Provide all working condition parameters, and the protection configuration can be determined at once

The essence of overload protection is not to select one part, but to make a choice by putting four parameters including peak torque, inertia, frequency of start and stop, and allowable downtime. The parameters are incomplete, and any supplier can only estimate based on experience. Hangzhou Weigao Transmission's product line covers cycloidal pinwheel reducers , hard-toothed cylindrical gear reducers, worm gear reducers, helical and bevel gear reducers, planetary reducers, extruder-specific reducers and shaft-mounted reducers, and can be supplied in complete sets with torque limiters, hydraulic couplings and brakes. Send the motor power, output speed, load type and daily start and stop times, and the engineer will issue free plans and protection setting suggestions; you can also directly open the reducer online system and enter the parameters to compare the model yourself. As a reducer manufacturer , we also undertake customization of non-standard reducers . If you need a reducer quotation or reducer consultation , please contact Hangzhou Weigao Transmission ( Hangzhou reducer manufacturer , support drawings and samples).