WeiGao Transmission
Email: sales@wgt.net.cn
Language
通栏图2
tonglantu.jpg
Home / News / How to conduct energy efficiency test on R87-y7.5-4p-17.25 reducer

How to conduct energy efficiency test on R87-y7.5-4p-17.25 reducer

Author: Site Editor     Publish Time: 16-10-2026      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
How to conduct energy efficiency test on R87-y7.5-4p-17.25 reducer

1. Preparation before test

‌Equipment and data verification‌: Confirm the nameplate parameters (7.5kW, 4-pole motor, speed ratio 17.25), collect historical operating records, clean the oil stains on the box, and record the ambient temperature.

‌Instrument Selection calibration‌: Equipped with a torque speed sensor with an accuracy of ±0.2% FS, a power analyzer, as well as an infrared thermometer and a vibration meter. All instruments have been calibrated in advance.

‌Installation and safety confirmation‌: Fix the reducer on the test bench, connect the input end to the 7.5kW drive motor, and the output end to the magnetic powder/eddy current loading device, correct the coupling coaxiality to ≤0.05mm, and complete the safety isolation of power outage and tagout.

‌Lubrication status confirmation‌: Add the designated brand of industrial gear oil, control the oil level at the center line of the sight glass, and keep the breather unobstructed.

2. No-load energy efficiency pre-test

Run at 30%, 50%, and 80% of the rated speed for 10 minutes each. If there is no abnormality, increase to the rated speed and run continuously for 2 hours.

Record data every 20 minutes: no-load power, input and output speed, oil pool temperature, bearing seat temperature, vibration speed effective value.

Qualification judgment: The oil temperature is stable at 40~55℃, the high-speed shaft bearing temperature is ≤90℃, the vibration speed is ≤4.5mm/s, and there is no sticking, abnormal noise or oil leakage.

3. Actual measurement of graded load energy efficiency

After the no-load is passed, it is loaded step by step, reaching 25%, 50%, 75%, and 100% of the rated load in sequence, and each working condition runs stably for 30 minutes.

The ‌input power, output power, input torque, and output torque‌ under each working condition are collected simultaneously, and the energy efficiency value is calculated through the formula transmission efficiency η = output power ÷ input power × 100%.

Under rated load, the transmission efficiency of this R series hard tooth surface reducer should be ≥90%, and the efficiency fluctuation at each load point should not exceed ±2%.

4. Thermal balance and energy efficiency verification

Continuously operate at 100% rated load, and monitor the oil pool temperature every 10 minutes until the temperature difference of three consecutive measurements is ≤1°C to determine thermal balance.

Record the final thermal balance oil temperature, which requires the oil temperature to be ≤80°C, the temperature rise of the bearing seat (the difference between the temperature of the bearing and the environment) to be ≤40°C, and no local hot spots.

Correct energy efficiency results based on temperature rise data: If the oil temperature exceeds the standard, abnormal lubrication loss needs to be checked, and the efficiency value must be remeasured to eliminate invalid data.

5. Test closing and data archiving

After unloading and shutting down, recheck the tooth surface contact spots and sealing status to confirm that no component damage was caused by the testing process.

Organize the original data of all working conditions, generate energy efficiency test reports, mark key background information such as ambient temperature, loading method, instrument accuracy, etc., and keep them for long-term archiving.