When calculating the reducer Selection, first distinguish the load type, and then discuss the model.

The same 5.5 kW motor can be used on a belt conveyor for ten years, but may cause problems in three months on a winding machine. The reason is not the motor or the frame size, but the calculation of the reducer Selection is not checked according to the torque-speed relationship of the load. Loads at industrial sites are roughly divided into three categories: constant torque load, 、constant power load and square torque load . The calibration standards of the three are completely different - one type depends on the operating torque, one type depends on the limits at both ends, and one type should not rely on the speed reducer at all. This article explains clearly the calculation order, coefficient values ​​and common calculation errors of the three types of loads at once, and provides a list of values ​​that can be filled in directly on site.

Comparison of the torque-speed relationship of three types of loads

To determine the load type, what matters is not the name of the equipment, but "how the torque changes when the rotational speed changes". Both are mixers, the blades have constant torque in the liquid, while the belt coilers have constant power; both are fans, the centrifugal type has close to square torque, but the Roots type has close to constant torque. If classified into wrong categories, all subsequent calculations will be biased.

Load type

Typical equipment

Torque and speed relationship

Selection Calibration benchmark

constant torque

Belt conveyor, screw conveyor, scraper, mixer, extruder, elevator

T is basically constant, and P is proportional to n

Running torque + starting torque peak, also check low-speed heat dissipation

constant power

Winding machine, unwinding machine, machine tool spindle, some coating and printing units

P is constant, T is inversely proportional to n

Peak torque at low speed end (full coil) + rotational speed at high speed end (hollow core)

square torque

Centrifugal fans, water pumps, cooling tower fans, centrifugal blowers

T is proportional to n², P is proportional to n³

Select according to the shaft power at the actual operating speed. Frequency conversion is preferred for speed regulation.

shock/pulsation

Crusher, press, lifting, reciprocating mechanism with frequent forward and reverse rotation

Periodic peaks are superimposed on the steady state

Calibrate according to peak torque × 1.5~2.5, do not look at the average value

First decide which category the equipment belongs to, and then start the calculation. In this step, you only need to ask three questions: Does the resistance of the equipment remain unchanged when adjusting the speed? How does power vary with speed? Are there any cyclical shocks?

Constant torque load: selected according to running torque, calibrated according to starting torque

Constant torque is a category with a high proportion of industrial sites. The calculation sequence is: first calculate the load torque from the resistance, then inversely estimate the power from the output speed, then multiply the reducer service coefficient to obtain the required rated torque, and finally check the starting moment independently. The basic formula is still T = F×r and P = T·n/9550, where r is the radius of the transmission roller, and P needs to be divided by the transmission efficiency before taking the motor gear upward.

Example: The conveying mass of the belt conveyor is 3000 kg, the comprehensive friction coefficient is 0.12, the diameter of the transmission roller is 400 mm, and the belt speed is 0.8 m/s. Tangential force F = 0.12×3000×9.8 ≈ 3528 N, load torque T = 3528×0.2 ≈ 706 N·m; output speed n = 0.8×60÷(π×0.4) ≈ 38 r/min; shaft power P = 706×38÷9550 ≈ 2.8 kW, divided by efficiency 0.94 The output is 3.0 kW, and the motor is in 4 kW gear. The required rated torque of the reducer is calculated as 706×1.4 ≈ 990 N·m based on the service factor of 1.4. Then check whether the allowable output torque of the machine base at 38 r/min in the sample is covered.

What tends to leak is startup. For conveyors that start with load and screw machines that start with full material, the starting torque can reach 1.8 to 2.5 times the operating torque, that is, 1270 to 1765 N·m. This value must fall within the instantaneous torque range marked on the sample (usually 80% of the instantaneous torque is used). This also explains why the conveyor reducer frequently breaks teeth or breaks the shaft at the moment of startup - the operation is stopped after selecting the operating torque, and no one takes into account the startup conditions.

Another detail: When the frequency conversion is reduced to less than 30% of the rated speed for long-term operation, the heat dissipation capacity of the motor that relies on axial flow fan self-cooling is significantly reduced, and the splash lubrication of the reducer itself is also deteriorated. For such working conditions, a variable frequency motor with an independent cooling fan should be selected, or the continuous operating speed should be controlled above 50% of the rated value. Otherwise, the temperature rise will be more than ten degrees higher than the rated working condition, and the oxidation of the lubricating oil will be accelerated.

Constant power load: both ends must be checked

Winding equipment operates at a constant linear speed. As the winding diameter increases, the torque increases and the rotational speed decreases, but the power remains approximately unchanged. The calibration of constant power load cannot only look at one point: the torque at the full coil end reaches the peak value, the speed at the hollow end reaches the peak value, and both ends must fall within the allowable range of the reducer.

Calculation method: drum torque T = F×R÷η (F is tension, R is current roll radius); drum speed n = v÷(2πR) (v is linear speed). Assuming the tension is 800 N, the full roll radius is 0.5 m, the hollow core radius is 0.1 m, the linear speed is 120 m/min, and the efficiency is 0.92, then the full roll end T = 800×0.5÷0.92 ≈ 435 N·m, n ≈ 38 r/min; the hollow end T ≈ 87 N·m, n ≈ 191 r/min. The roll diameter ratio is 5:1, and the corresponding speed range is also 5:1.

From this, two Selection conclusions are drawn: the reducer selects the rated torque based on 435 N·m at the full coil end and multiplied by the service factor (winding tension fluctuation is 1.3~1.6); the motor power is calculated once at both ends according to P = T·n/9550 and the larger value is obtained. In this example, the full coil end is about 1.7 kW and the hollow end is about 1.7 kW, indicating that the constant power characteristic is established. If the roll diameter ratio is larger than 8:1, you must also confirm the constant torque output capability of the motor at the low speed end and the low-frequency torque boost setting of the inverter. Do not let the motor be forced around 5 Hz.

Also pay attention to reversal and braking during uncoiling conditions: the dead weight of the material roll will drag the shaft system to accelerate, and the self-locking of the worm gear alone is not reliable. Under dynamic conditions, a brake or a frequency conversion solution with a braking resistor must be equipped. This point is directly related to the braking torque calibration in the reducer Selection and cannot be omitted.

Square torque load: why most fans and water pumps do not rely on speed reducers for speed regulation

Centrifugal fans and water pumps follow similar laws: flow is proportional to the rotational speed, pressure is proportional to the square of the rotational speed, and shaft power is proportional to the cube of the rotational speed. When the speed drops to half, the shaft power is only one-eighth. This is the fundamental reason why variable frequency speed regulation can significantly save energy on fans and water pumps.

Speed ​​(relative rated)

100%

90%

80%

70%

60%

50%

Shaft power (relative rating)

100%

72.9%

51.2%

34.3%

21.6%

12.5%

Power saving rate relative to 100% speed

—

27.1%

48.8%

65.7%

78.4%

87.5%

Therefore, for this type of load, the positioning of the reducer is "fixed speed reduction matching" rather than "speed regulation means": if the cooling tower fan or boiler induced draft fan needs to be fixed at a low speed due to structural reasons, the reducer is selected according to the reduced shaft power, not the motor nameplate power; if the process requires variable flow, priority is given to frequency conversion, and the reducer only undertakes one fixed deceleration. On the contrary, using a reducer to keep the fan speed fixed and low, and then using a valve or baffle to adjust the flow, consumes electric energy in throttling, and the operating cost is much higher than that of a frequency converter.

Another reminder: Positive displacement equipment such as Roots blowers, screw compressors, and plunger pumps have constant torque characteristics. Cube law cannot be applied and calculations are based on the constant torque method. This point causes errors when matching the motor power to the reducer .

Three-type load coefficients and calibration table

project

constant torque

constant power

square torque

Calculate datum point

Steady state operating point

Full roll end + hollow end two points

Actual operating speed point

Service factor value

1.25~1.5 (even to medium impact)

1.3~1.6 (Take the upper limit of tension fluctuation)

1.1~1.3

Peak calibration

Start 1.8~2.5 times operating torque

Tension impact at the moment of material breakage and roll change

The starting inertia is small, just press 1.2 times

Key points of thermal calibration

Low speed and heavy load continuous operation

High torque and heat at low speed end

Generally not overheated unless the speed is lower than 30% for a long time

Common miscalculations

Only counts running, not startup

Only press the full roll selection, the hollow end will speed up

Apply the cubic law to calculate volumetric equipment

Four items to review after calculating torque

Torque is just the entrance. The four reviews are as follows: first, the thermal power check of the reducer . Sufficient mechanical strength does not mean sufficient heat dissipation. For continuous operation, compare it with the actual thermal power according to Pct = P×KT×KW; second, the peak value and instantaneous torque, directly discount the sample marked value; third, inertia and start and stop frequency, the converted inertia is calculated by J_load/i². When the inertia ratio is too large, the starting current and tooth surface impact will increase; fourth, the installation attitude and environment, M1~M6 Different installation locations correspond to different oil levels, and there are also additional protection level requirements for dust, moisture, and outdoor use.

The speed ratio calculation of the reducer determines whether the output speed can fall within the process window: i = n₁/n₂. In actual Selection, take the standard gear and check it nearby. If the speed ratio is too large, the output speed will be insufficient, and if the speed ratio is small, the torque will be insufficient. Both ends will affect the calculation results of the reducer output torque .

On-site pick-up list: Complete the seven items to get a plan

Collect the following seven items. Most working conditions can be calculated accurately at one time, without the need to confirm back and forth: 1. Equipment type and load properties (constant torque/constant power/square torque); 2. Load resistance or tension, as well as radius of action and roll diameter range; 3. Output speed or linear speed required by the process; 4. Daily Operating hours, frequency of start and stop, whether forward and reverse rotation; 5. Installation method and output shaft connection form (solid shaft, hollow shaft, flange, torque arm); 6. Environmental conditions (temperature, dust, water washing, corrosion, altitude); 7. Power supply parameters (voltage, frequency, whether frequency conversion is required, whether braking is required). If only the motor power and output speed can be provided on site, the first version of the plan can be produced based on the experience coefficient, and then the data can be supplemented for review.

Handing the parameters to engineers saves time rather than repeatedly testing the machine.

Once the calculation of the reducer Selection for the third type of load is done correctly, Selection is more than half done; the remaining work is to determine the specific machine base, speed ratio and configuration. If you have specific working conditions - load type, torque or tension, output speed, operating hours and installation method, please contact Hangzhou Weigao Transmission . We provide a complete product line of cycloidal pinwheel reducers, hard-tooth surface cylindrical gear reducers, worm gear reducers, planetary reducers and gear reduction motors. As a reducer manufacturer , we can provide free Selection plans and reducer quotations based on parameters . We also support reducer customization and comparison with imported brand models. If you need to calculate it yourself first, you can open the Weigao transmission reducer online Selection system, enter the motor power, speed and torque to get the candidate configuration; if you have any questions, you are welcome to directly consult the reducer Selection。