WeiGao Transmission
Email: sales@wgt.net.cn
Language
通栏图2
tonglantu.jpg
Home / News / How to Select a Gear Motor: Torque, Speed Ratio and Thermal Power Explained

How to Select a Gear Motor: Torque, Speed Ratio and Thermal Power Explained

Author: Site Editor     Publish Time: 11-10-2026      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Choosing the right gear motor is one of the most important decisions in machine design. An undersized gear reducer fails early; an oversized one wastes energy and money. This guide walks through the three core parameters every engineer should verify: torque, speed ratio (gear ratio) and thermal power.

Step 1: Calculate the Required Power and Torque

The basic motor power formula is:

P = (T × n) / 9550

where P is motor power in kW, T is load torque in N·m, and n is output speed in r/min. In real applications, apply a service factor (K = 1.2–2.0) depending on load characteristics: uniform loads (conveyors, fans) use lower values, while medium or heavy shock loads (crushers, mixers, hoists) require higher values.

Step 2: Determine the Gear Ratio

The speed ratio of a gear reducer is simply:

i = n₁ (input speed) / n₂ (required output speed)

Example: a 1450 r/min motor driving a conveyor at 30 r/min needs a ratio of about 48:1, which can be achieved with a two-stage helical gearbox or a cycloidal (pin-wheel) reducer. Keep the actual ratio within 5% of the theoretical value where possible.

Step 3: Verify Torque Capacity and Service Factor

The rated output torque of the gearbox must satisfy:

T₂ = T₁ × i × η (η = transmission efficiency)

Typical efficiency values: planetary gear reducers 0.92–0.97, helical gear units 0.94–0.96, worm gear reducers only 0.7–0.85. For applications with frequent starts, the peak torque must not exceed the rated torque of the gearbox (generally keep short-term overload below 150–200%).

Step 4: Check Thermal Power for Continuous Duty

For continuous operation, the allowed thermal power rating of the gear reducer must be higher than the actual transmitted power multiplied by ambient correction factors. Above 40°C ambient temperature, apply a correction factor of 1.1–1.3. If the thermal check fails, consider a larger frame, forced cooling, or a synthetic lubricant.

Step 5: Match Mounting, Backlash and Environment

  • Mounting: confirm flange size, shaft diameter, hollow/shaft output type and maintenance clearance.

  • Backlash: precision positioning applications require ≤3 arcmin; general machinery can accept 8 arcmin or more.

  • Protection: choose IP54 for normal workshops, IP65 or above for dusty or wet environments.

  • Lubrication: most industrial gear reducers require an oil change every 8,000–10,000 running hours; worm units every 4,000–6,000 hours.

Common Selection Mistakes to Avoid

1. Sizing only by motor nameplate power while ignoring cyclical load peaks — use the RMS load method for fluctuating duty cycles.
2. Chasing an overly large ratio in a single stage, which causes efficiency loss and excessive backlash.
3. Ignoring radial load on the output shaft — verify the allowed overhung load against chain sprocket or pulley pulls.
4. Forgetting altitude and ambient temperature derating above 1,000 m.

Following this checklist, engineers can match the right gear motor and gear reducer combination for stable, energy-efficient operation. For help selecting a replacement gearbox compatible with SEW, NORD, BLD cycloidal series and more, contact the WGT Gearbox engineering team — we provide free selection support based on your torque, speed and mounting requirements.

Latest News

WeiGao Transmission

Weigao Gear Reducer is an alliance group company that integrates research and development, production, sales, and service

+86 400 801 9158

Email: sales@wgt.net.cn;wgt.net.cn@gmail.com
Tel:+86571 85023000

WEIGAO REDUCER

FEEDBACK