When the WBE1510-WD731-750 cycloidal reducer motor over-cuts and trips, follow this process to quickly troubleshoot:
1. Immediate power outage and preliminary judgment
Emergency treatment: Cut off the power immediately after tripping, touch the motor and reducer housing to determine whether the temperature is abnormal.
Manual turning: Check whether the transmission system is stuck.
Preliminary measurement: Use a multimeter to measure the three-phase current and voltage of the motor to initially distinguish whether it is an electrical fault or a mechanical fault.
2. Inspection by module
1. Electrical system inspection:
Insulation Test: Use a 500V megger to measure the insulation resistance of the motor winding to ground. The normal value should be >0.5MΩ.
Three-phase balance test: Use a clamp ammeter to measure the operating current. The three-phase unbalance should be <10%.
Protective device inspection: Check whether the circuit breaker, fuse, and thermal relay are normal.
2. Mechanical system inspection:
Load end inspection: Remove the load and test run. If no load is normal, check whether the pump, fan and other load machinery are stuck.
Bearing status assessment: Judging from the listening stick and vibration detector, if abnormal noise or vibration value exceeds the standard (>2.8mm/s), the bearing must be replaced immediately.
3. Troubleshooting and verification
1. Repair the identified fault points:
Electrical failure: Repair or replace the winding, and re-dip in paint if necessary.
Mechanical failure: Clean stuck parts and adjust the load.
2. Trial run verification:
First conduct a no-load test run (30 minutes) to monitor current, temperature, and vibration data.
Then gradually load it to 50%, 80%, and 100% of the rated load. Run each level of load for 1 hour. Only after confirming that there is no tripping phenomenon can it be put into normal operation.
What should you pay attention to when verifying the FA series gear reducer with load?
NGW-L11-5.6 Preventive methods for base settlement and cracking of planetary reducer
How to detect whether the output shaft is damaged when installing DCY160 gear reducer
Analysis on the Necessity of Output Shaft Damage Inspection before Installation of DCY200 Reducer
How to accurately solve the problems of vibration, jitter and unstable speed of loom reducer
Optimize the operation and maintenance of loom reducer to reduce downtime losses
Can the FAF67-4.21-4KW reducer cooling fan operate normally?
How to choose seals for TY115-18-7.5KW hard tooth surface reducer
WS280-63-4F worm gear reducer maintenance cycle and maintenance precautions
NGW-L112-71 planetary reducer base reinforcement and load-bearing enhancement measures
How to check and adjust the worm gear meshing state of WPWA155-50-B reducer?
Hard tooth surface reducer vs soft tooth surface reducer: how to set the lubrication cycle
What instruments are used to detect the vibration of the NGW61-3.15 planetary gear reducer base?