When the WBE1510-WD731-750 cycloidal reducer motor over-cuts and trips, follow this process to quickly troubleshoot:
1. Immediate power outage and preliminary judgment
Emergency treatment: Cut off the power immediately after tripping, touch the motor and reducer housing to determine whether the temperature is abnormal.
Manual turning: Check whether the transmission system is stuck.
Preliminary measurement: Use a multimeter to measure the three-phase current and voltage of the motor to initially distinguish whether it is an electrical fault or a mechanical fault.
2. Inspection by module
1. Electrical system inspection:
Insulation Test: Use a 500V megger to measure the insulation resistance of the motor winding to ground. The normal value should be >0.5MΩ.
Three-phase balance test: Use a clamp ammeter to measure the operating current. The three-phase unbalance should be <10%.
Protective device inspection: Check whether the circuit breaker, fuse, and thermal relay are normal.
2. Mechanical system inspection:
Load end inspection: Remove the load and test run. If no load is normal, check whether the pump, fan and other load machinery are stuck.
Bearing status assessment: Judging from the listening stick and vibration detector, if abnormal noise or vibration value exceeds the standard (>2.8mm/s), the bearing must be replaced immediately.
3. Troubleshooting and verification
1. Repair the identified fault points:
Electrical failure: Repair or replace the winding, and re-dip in paint if necessary.
Mechanical failure: Clean stuck parts and adjust the load.
2. Trial run verification:
First conduct a no-load test run (30 minutes) to monitor current, temperature, and vibration data.
Then gradually load it to 50%, 80%, and 100% of the rated load. Run each level of load for 1 hour. Only after confirming that there is no tripping phenomenon can it be put into normal operation.
Which light-load equipment is suitable for ZDY series gear reducer?
What is the working principle of the overload protection device of BWD27 cycloid reducer?
Failure warning technology of rice mill reducer: realizing preventive maintenance
Lightweight design and convenient maintenance of small rice mill reducer
How does the cutter reducer solve the torque bottleneck of heavy-duty cutting of servo motors?
What impact does installation deviation have on the output shaft of R series gear reducer?
What specific faults will the installation deviation cause in the R series reducer?
The hidden impact of the lubrication method of the cutting machine reducer on the life and accuracy
How to determine the installation direction of ZSY gear reducer backstop
What are the specific consequences if the backstop of the ZSY reducer is installed upside down?
How to solve the problem of broken shaft of planetary reducer
Is the reducer noisy? Find the reasons from gear modification to box design
Full analysis of lathe reducer installation: misalignment is an accuracy killer!
What are the steps to adjust the oil level of DCY gear reducer?
What are the fracture characteristics of fatigue fracture of ZSY reducer spline shaft?
How to replace the internal parts of WB micro cycloidal reducer
How to judge whether the arm bearing of WB micro cycloid reducer needs to be replaced
Three major causes of overload failure of palletizer reducer
How to reduce the impact of low temperature environment on SAF series reducer
Do KAF series reducer bearings need special protection in low temperature environments?
Idle storage and restart operation and maintenance specifications of sizing machine reducer
The hidden impact of speed ratio matching of sizing machine reducer on yarn quality