Author: WGT. Publish Time: 27-12-2021 Origin: WGT
First, check that the power to the AC relay and thermal protection relay is normal.If there is an abnormal problem, you need to check the power supply and restore the normal power supply of the power supply.
The second generation is to detect whether the winding coil of the AC relay is damaged or worn, and then check the magnet for rust.If so, remove the rust from the magnets during actual maintenance.If the coil is damaged, it must be replaced in time.
The third is to detect whether the winding of the AC relay has a short circuit problem.If there is no short circuit, continue to test whether the wiring contact of the thermal protection relay is unobstructed.If there is a short, repair the AC relay directly so that its contacts can make good contact.
How to deal with abnormal noise in the reducer gear during operation
Oil level maintenance and oil replenishment specifications for WPKS155-60 worm gear reducer
What is the function of the oil level sight glass of WPA worm gear reducer?
What are the common causes of oil leakage in NGW122-8 reducer?
What are the differences in the installation methods of ZSY reducer and DCY gear reducer?
What measures should be taken immediately when the WP series worm reducer is overloaded?
Which light-load equipment is suitable for ZDY series gear reducer?
What is the working principle of the overload protection device of BWD27 cycloid reducer?
Failure warning technology of rice mill reducer: realizing preventive maintenance
Lightweight design and convenient maintenance of small rice mill reducer
How does the cutter reducer solve the torque bottleneck of heavy-duty cutting of servo motors?
What impact does installation deviation have on the output shaft of R series gear reducer?
What specific faults will the installation deviation cause in the R series reducer?
The hidden impact of the lubrication method of the cutting machine reducer on the life and accuracy
How to determine the installation direction of ZSY gear reducer backstop
What are the specific consequences if the backstop of the ZSY reducer is installed upside down?
How to solve the problem of broken shaft of planetary reducer
Is the reducer noisy? Find the reasons from gear modification to box design
Full analysis of lathe reducer installation: misalignment is an accuracy killer!
What are the steps to adjust the oil level of DCY gear reducer?
What are the fracture characteristics of fatigue fracture of ZSY reducer spline shaft?