| SKU: | |
|---|---|
| Availability: | |
| Quantity: | |
The SWC-|A lightweight cross-shaft universal coupling (catalogue designation SWC-Ⅰ A type) is the telescopic welded member of WGT's SWC cross-shaft programme. Two shafts that cannot be lined up are joined through a cross joint, so a real axis angle can be absorbed while torque is still transmitted smoothly and continuously. The A type adds a sliding telescopic sleeve between the fork yokes, giving a telescopic welded universal coupling with an axial stroke that takes up thermal growth, frame movement or mounting error without moving the driven machine. Ten sizes run from SWC-Ⅰ 58 to SWC-Ⅰ 225, with nominal torque from 180 N·m to 22 000 N·m and a maximum working axis angle of 35° on the small and medium sizes. Compared with the small fixed-pin joints of the CSKA and WS series, the light cross-shaft build carries far more torque per joint, tolerates shock far better and still keeps rotating inertia low for machinery that starts and stops repeatedly. The wider SWC cross-shaft programme in the same WGT catalogue is supplied under JB/T 5531-1991.
| Item | Typical Range | Notes |
|---|---|---|
| Series designation | SWC-Ⅰ 58 to SWC-Ⅰ 225, 10 sizes | Light cross-shaft type; A type is the telescopic welded version |
| Nominal torque Tn | 180 – 22 000 N·m | Catalogued at 50 % of yield torque |
| Fatigue torque Tf | 90 – 11 000 N·m | Permissible torque under reversing load, set by fatigue strength |
| Maximum axis angle β | 35° (58 to 150), 25° (180 to 225) | Single joint; total angle of a double-joint train is shared between the two joints |
| Rotation diameter Df | 58 – 225 mm | Equals the model designation |
| Telescopic stroke LV (A type) | 35 – 120 mm | Axial movement the sleeve can take up |
| Mass (A type) | 2.2 – 128 kg | B and C types weigh less at every size |
| Flange bolts | M5 to M16, 4 / 6 / 8 holes | Bolt torque TK 7 – 270 N·m; hole pitch 45° (4), 60° (6), 22.5°/45° (8) |
Values are WGT catalogue figures for the standard range; the actual selection has to be calculated from the working torque, the duty coefficient, the angle error and the axial movement of the installation.
| Model | Tn (N·m) | Tf (N·m) | β (°) | A type L (mm) | LV (mm) | Mass (kg) | Flange bolts | TK (N·m) |
|---|---|---|---|---|---|---|---|---|
| SWC-Ⅰ 58 | 180 | 90 | 35 | 255 | 35 | 2.2 | M5 | 7 |
| SWC-Ⅰ 65 | 240 | 120 | 35 | 285 | 40 | 3 | M6 | 13 |
| SWC-Ⅰ 75 | 500 | 250 | 35 | 335 | 40 | 5 | M6 | 13 |
| SWC-Ⅰ 90 | 800 | 400 | 35 | 385 | 45 | 6.6 | M8 | 32 |
| SWC-Ⅰ 100 | 1200 | 600 | 35 | 445 | 55 | 9.5 | M8 | 32 |
| SWC-Ⅰ 120 | 2300 | 1150 | 35 | 500 | 80 | 17 | M10 | 64 |
| SWC-Ⅰ 150 | 4500 | 2250 | 35 | 590 | 80 | 32 | M12 | 110 |
| SWC-Ⅰ 180 | 8400 | 4200 | 25 | 640 | 80 | 40 | M14 | 180 |
| SWC-Ⅰ 200 | 16000 | 8000 | 25 | 775 | 100 | 76 | M16 | 270 |
| SWC-Ⅰ 225 | 22000 | 11000 | 25 | 860 | 120 | 128 | M16 | 270 |
For a telescopic type, L is the standard length measured with the sleeve fully retracted. Tn is the nominal torque taken at 50 % of yield torque, Tf the permissible torque under reversing load determined by fatigue strength, and β the maximum axis angle.
| Model | D (mm) | Df (mm) | D1 (mm) | D2 (mm, H9) | D3 × δ (mm) | Lm (mm) | K (mm) | t (mm) | mL (kg) |
|---|---|---|---|---|---|---|---|---|---|
| SWC-Ⅰ 58 | 52 | 58 | 47 | 30 | 38 × 1.5 | 32 | 3.5 | 1.5 | 0.14 |
| SWC-Ⅰ 65 | 63 | 65 | 52 | 35 | 45 × 1.5 | 39 | 4.5 | 1.7 | 0.16 |
| SWC-Ⅰ 75 | 72 | 75 | 62 | 42 | 63.5 × 2.5 | 45 | 5.5 | 2.0 | 0.38 |
| SWC-Ⅰ 90 | 92 | 90 | 74.5 | 47 | 63.5 × 2.5 | 52 | 6.0 | 2.5 | 0.38 |
| SWC-Ⅰ 100 | 100 | 100 | 84 | 57 | 89 × 2.5 | 55 | 8.0 | 2.5 | 0.53 |
| SWC-Ⅰ 120 | 112 | 120 | 101.5 | 75 | 89 × 2.5 | 63 | 8.0 | 2.5 | 0.53 |
| SWC-Ⅰ 150 | 142 | 150 | 130 | 90 | 120 × 3 | 85 | 10.0 | 3.0 | 0.87 |
| SWC-Ⅰ 180 | 154 | 180 | 155.5 | 110 | 120 × 3 | 87 | 12.0 | 4.0 | 0.87 |
| SWC-Ⅰ 200 | 187 | 200 | 170 | 125 | 127 × 5.5 | 110 | 14.0 | 4.0 | 1.65 |
| SWC-Ⅰ 225 | 204 | 225 | 196 | 140 | 140 × 6.5 | 120 | 15.0 | 5.0 | 2.14 |
Df is the rotation diameter and equals the model designation, D2 is the shaft bore in H9 fit, and D and D1 are the two further principal diameters marked on the type drawing. D3 × δ gives the tube outside diameter and its wall thickness δ; Lm, K and t are the fork length, the flange offset and the flange thickness marked on the same drawing. mL is the added mass for every 100 mm of extra length. Dimensions not stated in the catalogue are in millimetres.
A packaging machine drives a drum from a 7.5 kW, 960 r/min motor. The drum shaft is offset from the motor by 8° and moves 40 mm axially as the machine runs, so a telescopic cross-shaft coupling is used.
Step 1 – Working torque. T = 9550 × P / n = 9550 × 7.5 / 960 = 74.6 N·m.
Step 2 – Service factor. Packaging machinery is a light-shock duty, so the SWC duty coefficient K = 1.3 applies: design torque = 74.6 × 1.3 = 97.0 N·m. For reversing or fluctuating loads the fatigue torque Tf has to satisfy the same check instead of Tn.
Step 3 – Size. SWC-Ⅰ 58 carries Tn = 180 N·m, but its fatigue torque is only 90 N·m, below the 97 N·m design torque. Step up to SWC-Ⅰ 65: Tn = 240 N·m and Tf = 120 N·m, both above the design torque.
Step 4 – Angle and bore. The 8° misalignment is well inside the 35° maximum of the 65 size. The bore D2 = 35 mm in H9 fit has to suit the motor shaft journal, and the flange is drilled for M6 bolts on a 45° hole pattern, tightened to TK = 13 N·m.
Step 5 – Telescopic stroke. The A type of the 65 size has LV = 40 mm of stroke and a standard length L = 285 mm in the fully retracted state, so the 40 mm of axial movement is taken up by the sleeve. If the frame movement were larger than 40 mm, the next size up (SWC-Ⅰ 120, LV = 80 mm) would be needed.
Step 6 – Type check. Where no axial movement exists at all, the fixed-length B type or the short C type of the same size is lighter and cheaper, but it cannot absorb axial travel — only the A type can.
Equal angular velocity requires three conditions to be met: the inclination of the input and output shaft must be equal, the two forks on the intermediate shaft must be in the same phase, and the three shaft centre lines must lie in one plane. The installation is then defined as Z type (parallel shafts) or W type (intersecting shafts). Practical universal coupling selection always combines the torque check above with the angle, bore, stroke and flange checks; a universal joint torque calculation alone is not enough to fix the size, and the same discipline applies to any shaft coupling sizing job on the line.
Match motor power, speed, bore, angle error and axial movement against the full SWC-Ⅰ table in the WGT Motor & Gearbox Online Selection System — the fastest route through cross shaft coupling selection — and confirm size, type and flange pattern before ordering. For field service, universal coupling maintenance on this joint type is simple: grease the cross bearings and the telescopic sleeve at the maker's interval, check the sleeve for wear at the stroke limit, and verify the flange bolts to the catalogue torque TK after any disassembly.