What are the common failures of mixed reducing agents?How to solve it?
Publish Time: 2021-11-22 Origin: WGT
Through the recent return visits to customers, we found that although there are instructions, some customers still don't know much about the hybrid reducer, ignore some points that should be paid attention to, and can't give full play to the special reducer of the mixer.Today, we hope to discuss with you the disassembly and maintenance methods of the hybrid reducer, and I hope I can help you.
After long-term operation, the hybrid reducer will inevitably have some problems after long-term operation, which requires maintenance.The following is the disassembly and maintenance method of the reducer:
1. The cause of abnormal vibration failure: it is mainly caused by poor fixation of the transmission device, such as worn or damaged worm gear, worn or damaged bearing, and loose bolts.
Solution: Repair or replace the worm gear and tighten the bolts.
2. Reducer noise failure causes: poor meshing of worm gear and worm, damaged or excessive cleaning of bearings, insufficient lubricating oil, and foreign matter may enter.
Solution: Repair the contact surface of the teeth, add an appropriate amount of lubricating oil, remove foreign matter, and use an oil filter to treat the lubricating oil or replace the lubricating oil.
Disassembly method:
How to remove the upper casing of the gear reducer?If the reducer has a half-coupling, please take out the half-coupling first.Remove the fixing bolts and loosen the nuts.Don't lose them.Do not underestimate this work.Pay attention to it in ordinary times.Inspect the upper case for defects and cracks.Mark the assembly mark and remove the bearing end shield.First check for missing bolts and other abnormalities.After confirmation, lift the upper case with the clip screws, lift it up and place it on the prepared bottom plate.