How to do daily inspection of reducer: daily inspection, weekly inspection and monthly inspection items list - Hangzhou Weigao Transmission
Publish Time: 2026-10-26 Origin: Site
Why should reducer maintenance start with inspection?
Among all the work of reducer maintenance, inspection is a part that requires little investment and yields quick results. Industry experience statistics show that more than 60% of reducer failures are related to poor lubrication, loose bolts and seal failure, and these three types of problems can almost be discovered in advance during daily inspections. The purpose of inspection is not to "do more", but to turn unexpected shutdowns into planned maintenance.
Classification by cycle: The frequency of inspections follows the rate of deterioration
The speed of different deterioration processes varies greatly: the abnormal noise of an oil leakage 、reducer is measured in days; loose bolts and oil emulsification are measured in weeks and months; tooth surface pitting and bearing wear are measured in months and years. Classifying inspection items by day, week, month, and quarter can not only prevent sudden failures, but also avoid unnecessary unpacking and inspection. Standards such as GB/T 6075.3 provide quantitative judgment lines for vibration and temperature, providing an objective basis for inspection records.
Five items of daily inspection: look, listen, touch, test and record
Complete every day after startup and before shutdown:
Check the oil level : Keep the oil window scale at 1/2 to 2/3; if it is lower than the lower limit, add the same brand of oil. Mixing is prohibited.
Check for oil leakage : check the shaft extension oil seal, joint surface, end cover, and oil drain plug point by point; refer to JB/T 9050.3, and the acceptable level is no more than 3 drops of oil leakage per hour.
Listen to the sound : Sharp whistling is mostly due to lack of oil in the bearing. Periodic impacts indicate tooth surface or bearing damage. Continuous buzzing is often caused by loose or misaligned footings.
Touch the temperature : measure the shell and bearing position with an infrared thermometer. The temperature rise does not exceed 40 to 50 ℃, and the oil temperature does not exceed 80 ℃ (worm gear model does not exceed 85 ℃).
Keep records : Values and exceptions are written into the inspection table. Trends are more important than single values , which is where the value of checking records lies.
Four items of weekly inspection: ventilation, heat dissipation, fastening and coupling
Arrange once a week: Clean the vent cap , blockage will cause the internal pressure of the box to increase and accelerate leakage; clean the heat dissipation ribs and the dust accumulated in the box, which is equivalent to the insulation layer and directly pushes up the oil temperature; spot-check the foot and end cover bolts, and retighten the torque to ±10% of the design value; check whether the elastic block of the coupling is cracked and whether the alignment moves.
Three monthly inspections: vibration, temperature difference and oil sample appearance
Use a vibration meter every month to measure the input end, output end bearing seat and the middle part of the box: the vibration speed effective value is 2.8~4.5 mm/s, which is good. If the vibration speed exceeds 7.1 mm/s, the machine must be stopped. When the temperature difference between the bearing position and the box exceeds 15°C, recheck this part. Take a small amount of oil sample from the oil drain port and observe: if it is clear and tan, it is normal. If it is white, emulsified, black or has metal powder, arrange an oil change and trace the source of wear.
Quarterly and annual maintenance: oil change, oil inspection and cap opening inspection
Quarterly projects: Oil samples are sent for inspection (moisture content is ≤0.1%, viscosity change is within ±10%, and acid value does not exceed the standard); oil changes are arranged according to working conditions. Mineral gear oils are generally 2000 to 3000 hours or half a year, and the cycle is halved under high temperature, dust, and heavy load conditions. Annual project: Open the cover and check the pitting corrosion area of the tooth surface (less than 5%, you can continue to use it and take photos for files), tooth thickness wear (replacement if more than 10%), bearing clearance and contact spot distribution.
Inspection cycle and judgment value quick check list
cycle | Check items | Judgment value/disposition |
|---|---|---|
daily | Oil level, oil leakage, abnormal noise, oil temperature | Oil level 1/2~2/3; oil leakage ≤3 drops/h; oil temperature ≤80 ℃ |
weekly | Ventilation cap, cooling ribs, bolts, couplings | Smooth, no dust accumulation; torque ±10% retightening |
per month | Vibration, bearing temperature difference, oil sample appearance | ≤4.5 mm/s; temperature difference ≤15 ℃; oil sample is clear |
quarter | Oil sample testing, oil change | Moisture ≤0.1%; mineral oil 2000~3000 h |
year | Open the cover and check the tooth surface and bearing clearance | Pitting corrosion <5%; tooth thickness wear >10% replacement |
How to use inspection records: three trend red lines
A single qualified value does not equal device health. It is recommended to set up three trend criteria, and arrange shutdown for investigation if any one is triggered: the oil temperature suddenly increases by 10°C compared with the baseline; the vibration value increases by 30% compared with the baseline; and the operating current increases significantly under the same working conditions. By keeping checklists, oil tests and vibration trends in the same record, problems can be signaled weeks in advance.
Hangzhou Weigao Transmission provides a complete product line of hard tooth surface reducers, cycloidal pinwheel reducers, worm gear reducers and gear reduction motors, and can provide inspection and maintenance recommendations based on working conditions. If you need a reducer manufacturer to customize a plan based on load or provide consultation , please contact the technical team.