Let me introduce in detail how to judge whether the worm gear joint surface of PWU160-40-V reducer is damaged.
Publish Time: 2026-11-18 Origin: Site
1. Preliminary judgment without dismantling the machine (daily inspection and quick screening)
Oil Characteristics Identification: Drop a small amount of old oil on white paper. If copper/black particles appear in the center of the oil spot, and there is a sandy feel when you rub it with your fingers, it means that wear debris has occurred on the joint surface. The copper filings ground by the tin bronze worm gear do not attract magnets, and can be used to distinguish the iron filings produced by the wear of steel gears.
Judgment of abnormal operating noise: Normal meshing is a smooth and low-noise buzzing sound. If there is a periodic impact sound (one sound per revolution), it indicates that there is pitting corrosion or local peeling on the joint surface; if a sharp high-frequency whistling sound occurs, it is most likely that the joint surface is glued or lubricated. Failure.
Vibration and temperature verification: Use a dial indicator to measure at the end of the worm shaft. The vibration amplitude exceeds 0.1mm and there is a numb pulse feeling, indicating that the meshing gap is too large. The surface temperature of the box exceeds 35°C and quickly soars to over 90°C within half an hour, indicating that the friction on the joint surface is abnormally intensified.
2. Quantitative verification (tools assist accurate judgment)
Measurement of meshing backlash: Use the lead pressing method or feeler gauge to detect the backlash of the worm gear pair. The standard backlash of the new PWU160 reducer is 0.1~0.3mm. When the actual measured value exceeds 0.5mm, it means that the wear of the joint surface has exceeded the safety threshold.
Tooth thickness wear measurement: Use a tooth thickness caliper to select 6 to 8 measuring points on the circumference of the worm gear, and measure segmentally along the tooth width direction. Compare it with the original design tooth thickness. If the tooth thickness reduction exceeds 10% of the original tooth thickness, it is determined that the joint surface is severely damaged.
Vibration spectrum analysis: Install a vibration sensor at the position of the box bearing seat to collect vibration signals in the 10~1000Hz frequency band. If the amplitude at the meshing frequency is 2~3 times higher than the baseline of the new machine, and obvious sidebands appear, it can be confirmed that there is uneven wear on the joint surface.
3. Disassembly and inspection (finally confirm the type and extent of damage)
Combining surface appearance inspection: Open the observation hole or end cover, and use a magnifying glass to observe the meshing area. Normally, the contact patch on the coupling surface has a uniform mesh texture, and the contact area is ≥70%. If there are continuous grooves along the sliding direction, local glue traces of copper material transferred to the worm surface, or the peeling pit area exceeds 20% of the tooth surface, it can be determined that the joint surface has been damaged.
Tooth profile accuracy verification: Use a gear measuring instrument to scan the entire tooth surface of the worm gear and compare it with the standard tooth profile. If the tooth profile deviation exceeds 0.08mm, it means that the joint surface has undergone irreversible tooth profile degradation, which will directly lead to a deterioration in transmission accuracy.
Contact mark verification: Evenly apply a very thin layer of red red powder on the tooth surface of the worm gear, and observe the mark distribution after manual turning for 3 to 5 turns. If the mark is only concentrated in the local area of the tooth top/root, rather than evenly distributed in the middle of the tooth surface, it indicates that the joint surface is meshed out of position, accompanied by eccentric wear damage.