The brake is not a motor accessory, but an Selection object that needs to be independently calibrated.
Gear reduction motors with brakes are often used in conveyor lines, elevators, packaging machines, and three-dimensional garages. However, when purchasing, they are often simplified into one sentence: 'Add a brake to the motor.' In actual on-site problems, it is often not that the motor power is insufficient, but that the brake side is not properly calibrated. The working logic of the power-off braking type electromagnetic brake is: when the coil is energized, the armature is attracted to the yoke, the compression spring, and the friction disk are separated, and the motor rotates freely; once the power is off, the spring presses the armature toward the friction disk, and the shaft is locked within tens to more than two hundred milliseconds. This means that the four parameters of braking torque, working air gap, release voltage, and braking frequency must be calculated together with the load. It is impossible to select accurately based on the motor nameplate power alone.
How to calculate braking torque: static holding and dynamic stopping are two paths
First, distinguish whether the load is 'stopped and not allowed to move' or 'rotated and must be stopped.' The former only needs to overcome the static moment, while the latter has to digest additional inertial kinetic energy. According to the reducer torque calculation formula T = 9550 × P ÷ n, first find the steady-state torque at the load end, and then multiply it by the working condition coefficient:
Working condition type | Calculation formula | Coefficient value | illustrate |
|---|---|---|---|
Lifting, vertical conveying (static maintenance) | T system ≥ K × T load | K = 1.5~2.0 | Leave a margin for the friction coefficient to decrease after the friction plate wears. |
Horizontal conveying, positioning shutdown (dynamic) | T system = J × Δω ÷ t + T load | Calculate back according to braking time t | The shorter t, the greater the torque. If it is too short, it will impact the transmission chain. |
Inclined belt and risk of sliding | Static + slope component | K takes the upper limit | The component of gravity along the inclined plane needs to be superimposed |
A quick calculation is commonly used in engineering: the braking torque is 1.5 to 2.5 times the rated torque of the motor. Below this range, the vehicle is prone to slippage during heavy-load shutdown; above this range, the impact torque at the moment of braking will be pushed back along the reducer to the input shaft, which may damage the gears and bearings in the long term. When making a reducer Selection , this step must be checked together with the service coefficient of the reducer , and cannot be calculated separately.
Air gap and friction plate thickness: two rulers for brake maintenance
The air gap is the air distance between the armature and the yoke, which is the most direct indicator of the brake status. The air gap is too large, and the electromagnetic suction force cannot pull it in place after power is turned on. The friction disc is in a semi-friction state, and the motor is dragging when it rotates. Abnormal heat sources often occur here due to temperature rise and reducer heating . The air gap is too small, and the armature's rebound stroke is insufficient after the power is turned off. The braking force output is insufficient, and the load is at risk of slipping. The air gap requirements are different for different frame sizes:
Motor frame number | Rated braking torque (N·m) | Working air gap (mm) | Air gap adjustment upper limit (mm) |
|---|---|---|---|
63/71 | 4/5 | 0.2 | 0.8 |
80/90 | 7.5/15 | 0.3/0.4 | 1.0 |
100/112 | 30/40 | 0.4/0.5 | 1.0 |
132/160/180 | 75/150/200 | 0.5 / 0.6 / 0.6 | 1.2 |
When adjusting, use a feeler gauge to measure three to four points on the circumference. Try to control the difference at each point within 0.05mm, otherwise the tilt of the armature will cause unilateral eccentric wear of the friction plate. It is a common practice to loosen the hollow bolt, clamp the feeler gauge in the air gap and then tighten it; after locking, retest, and then manually turn the machine to confirm that there is no continuous blockage. The thickness of the friction plate also has a lower limit. The new plate is mostly 5.5 to 13mm. It should be replaced when it is ground to about 50% of the original thickness or lower than the limit value given by the manufacturer. Do not "use the old plate to the end" by repeatedly adjusting the air gap.
Release the voltage and rectifier block: AC220 in, DC99 out, wrong connection will burn the coil
A common method for small brake motors is to install a rectifier block in the junction box to rectify the two-phase alternating current into direct current and send it to the excitation coil: AC220V to DC99V for base 100 and below, AC380V to DC170V for base 112 and above. There are three points to pay attention to at the scene: the two AC input lines of the rectifier block should be connected in parallel to the motor input end and cannot be connected in series behind the contactor for independent power supply, otherwise the back electromotive force at the moment of power outage will easily break down the rectifier block; the coil resistance can be measured with a multimeter. If the deviation from the nominal value exceeds ±10%, it can basically be determined that the coil is aging or an inter-turn short circuit; the manual release handle must be reset after debugging and cranking. Forgetting to reset means running with a "release" command for a long time, and a friction sound can be heard as soon as the power is turned on.
Frequency converter with brake motor: the three action sequences must be set correctly
When a frequency converter is used to drive with a holding brake a gear reduction motor , most of the faults come from the timing rather than the hardware. When starting, if the brake is loosened first and the torque is not established, the load will slide first and then be pulled, which is especially dangerous for lifting equipment; if the brake is closed first and the inverter is still outputting during shutdown, the friction plates will be quickly worn away during relative sliding. The reasonable approach is three steps:
One is the starting pre-torque. Set the starting pre-excitation or pre-torque to 20% to 30% of the rated torque, and wait until the inverter confirms that the torque is established before releasing the signal to the brake.
The second is the release and closing delay. The release delay is 0.1 to 0.5 seconds (0.3 seconds is enough in most cases); the shutdown follows the sequence of 'decelerate to 3~5 Hz → brake close → inverter stops output', and the closing action is arranged at the end of deceleration rather than the beginning of deceleration.
The third is deceleration time and braking resistor. If the deceleration time is too short, the regenerative energy pours back into the DC bus, and the bus voltage can instantly rush to 700~800V, triggering the overvoltage protection. Loads with large inertia should be equipped with a braking unit and a braking resistor. If necessary, DC braking should be superimposed for terminal holding, but the DC braking current should not exceed the rated current of the motor.
Braking frequency and friction work: Why replace brake pads three times a year with frequent inching?
Friction plates are consumables with a lifespan. The lifespan depends on the energy absorbed by each braking operation (friction work, unit J) and the accumulated energy per hour. If the same motor is used as a conveyor line to run continuously and start and stop dozens of times a day, the brake pads can be used for several years; if it is changed to positioning and inching, starting and stopping several times per minute, the friction work accumulation speed may be dozens of times higher than the former. It is not surprising to replace it three times a year. The solution to this type of working condition is not to increase the braking torque, but to set the minimum braking interval to more than 30 seconds (when the process allows), use the frequency converter to decelerate to bear the main braking energy, the mechanical brake is only used for terminal holding, and the calculation is based on the friction work per hour and friction work per hour limits given by the manufacturer Selection. When braking more than 10 times per minute, you should check with the manufacturer whether reinforced friction materials are needed.
On-site troubleshooting sequence for five common faults
Phenomenon | Common causes | deal with |
|---|---|---|
After powering on, there is still a friction sound and the casing is hot. | The air gap is too large, the suction fails, the manual release handle is not reset, and the output of the rectifier block is insufficient. | Retest the air gap, reset handle, and measure the DC output of the rectifier block |
Load slowly decreases after power outage | The air gap is too small, the friction plate is oily or thin, and the spring is fatigued | Clean the friction surface, replace the disc, and replace the spring set according to the instructions |
There is a "clang" sound when braking and the impact is obvious | The braking torque is too large, the deceleration time is too short, and the armature is deflected | Reduce the torque, extend the deceleration time, and re-adjust the air gap evenly |
The coil heats up or even burns out | The voltage level is wrongly connected, the rectifier block is broken down and then sent to AC, and the power is frequently energized. | Check the AC/DC matching, replace the rectifier block, and reduce the frequency of operations |
Frequency converter reports overvoltage | The deceleration time is too short and the braking resistor is not equipped. | Extend the deceleration time and install a braking unit and resistor |
Let’s get the parameters together and then talk about the model.
For with brakes gear reduction motors Selection, not only power and speed ratio need to be given: load torque, whether power-off maintenance is required, braking response time requirements, number of braking times per hour, installation direction (vertical installation requires confirmation of brake direction restrictions), and whether the on-site brake is directly closed or driven by a variable frequency drive. By putting these items together, the brake specifications and the installation method of the reducer can be determined at one time, and the subsequent reducer maintenance cycle can be included in the inspection list. If the site is already being towed or rolled, measuring the air gap and coil resistance first will often find the cause faster than replacing the entire machine.
Hangzhou Weigao Transmission provides transmission components for conveying, lifting, mixing, packaging and other equipment. The product line covers gear reduction motors, cycloidal pinwheel reducers, hard-tooth surface cylindrical gear reducers, worm gear reducers and planetary reducers. It can be equipped with electromagnetic brakes, frequency conversion special motors and various installation interfaces. As a reducer manufacturer , we provide free reducer consultation : send us the load torque, speed, braking frequency and installation direction, and the engineer will issue a plan and drawings including brake calibration, and you can directly open the reducer online system for self-service trial calculation. If you need to compare the prices of gear reduction motors , confirm the feasibility of customizing the reducer , or want to get a quote for the reducer , please contact Hangzhou Weigao Transmission, a reducer manufacturer in Hangzhou.