Most premature gearbox failures are not manufacturing defects — they are sizing errors. A unit rated to exactly the steady-state torque a conveyor demands has no margin for the 200–300% torque spike arriving at every motor start, and the damage shows up as tooth pitting, oil overheating and seal leakage long before design life. Closing that gap is the job of the service factor, and a properly documented service factor gearbox selection is the cheapest insurance in any drive train. This gearbox selection guide covers the formula, the AGMA and ISO reference values, two worked examples and the thermal check too many engineers skip.
What the Service Factor Actually Measures
The service factor (SF, written KA in ISO 6336-1) is the ratio between the torque a gearbox is rated to carry and the torque the machine actually requires. It exists because real drives never transmit constant torque: a nominally 75 kW motor delivers 200–300% of rated torque during direct-on-line starting, brief stall torque when a chute jams, and peak load when a belt starts fully loaded. Contact fatigue accumulates roughly with the sixth power of peak torque and bending fatigue with the eighth, so short transients consume life far faster than their duration suggests. A unit sized at SF = 1.0 has no reserve.
In ISO 6336 the application factor multiplies the nominal tangential force before every other step, so SF = 1.5 demands a larger module, wider face width, harder case, or all three. That is why the service factor cannot be quietly rounded up — it drives frame size, weight and cost.
The Service Factor Formula: Three Numbers You Need
Required output torque: T = 9550 × P ÷ n, with T in N·m, P in kW, n in rpm.
Actual service factor: SF = Trated ÷ Trequired.
Selection torque: Tselected = Trequired × SF — compare this, never the motor nameplate kW, with the catalogue rating.
A conveyor needing 500 N·m paired with a 500 N·m unit runs at SF = 1.0; pair it with a 750 N·m unit and SF = 1.5. Same motor, same duty, very different service life.
AGMA and ISO Reference Values
AGMA 2101 classifies drives by power-source against driven-machine character; ISO 6336-1 gives equivalent values. For electric-motor drives the practical bands are:
Machine character |
Typical applications |
SF (≤10 h/day) |
SF (24 h/day) |
|---|---|---|---|
Uniform |
Centrifugal pumps, light fans, steady conveyors |
1.00–1.25 |
1.25 |
Light shock |
Loaded conveyors, crane travel, machine tools |
1.25–1.50 |
1.50 |
Moderate shock |
Mixers, agitators, packaging indexers, mine hoists |
1.50 |
1.75–2.00 |
Heavy shock |
Crushers, cement kilns, reversing drives |
1.75–2.50 |
2.50–3.00+ |
Three corrections prevent most gearbox duty cycle selection mistakes: add about 10% above 10 running hours a day, add 0.25 if the motor starts direct-on-line with no soft starter, and add 0.2 for a diesel prime mover instead of an electric motor.
Worked Example: Gear Reducer Sizing Calculation for a Conveyor
Given: belt speed 3.0 m/s, head pulley 800 mm, motor base speed 1500 rpm, required power 75 kW, ambient 45 °C, dusty with regular starts.
Speed and ratio: pulley speed = 60 × 3.0 ÷ (π × 0.8) ≈ 71.6 rpm, so ratio ≈ 1500 ÷ 71.6 ≈ 21:1 — a helical-bevel unit. Torque: T = 9550 × 75 ÷ 71.6 ≈ 10,000 N·m. Apply SF: dusty duty with frequent starts is moderate shock, so SF = 1.5 and the selection torque is 15,000 N·m. Specify a unit rated at least 15,000 N·m at ~72 rpm. A screw conveyor handling dense abrasive material would justify 1.75; a reversing stacker-reclaimer drive, up to 2.5.
Service Factor Is Not Enough: Check the Thermal Power Rating
A gearbox can pass the torque check and still fail — gearbox overheating causes more seal leaks and oil breakdowns than overload. Every catalogue therefore publishes a second limit: thermal power rating gearbox tables stating the power the housing can dissipate continuously without exceeding the oil temperature limit (about 90–95 °C, usually on ISO VG 220). The thermal limit bites hardest at low output speed, high ratio and high ambient — exactly the conditions of a slow, heavily loaded conveyor. Above 40 °C ambient, correct the required power by 1.1–1.3 before comparing it with the thermal rating. If the unit fails thermally, choose a larger frame, add a cooling fan or coil, or switch to synthetic PAO oil that holds viscosity at 90–100 °C. Confirm the rating for your actual mounting position (M1–M6), since M5/M6 orientations reduce heat rejection.
How to Specify a Service Factor Gearbox: A 5-Step Checklist
Classify the machine as uniform, light, moderate or heavy shock and confirm daily running hours.
Calculate required torque with T = 9550 × P ÷ n, then multiply by the service factor for your duty class.
Select the frame whose rated output torque at the required speed meets or exceeds the selection torque.
Verify the thermal rating for your mounting position, ambient and duty cycle; add cooling or synthetic oil if marginal.
Check overhung load on the output shaft and confirm the mounting interface against your layout drawing.
Getting the service factor gearbox calculation right the first time costs nothing; discovering it was wrong costs a production stoppage. As a China gearbox manufacturer, WGT Gearbox builds helical inline, parallel-shaft, helical-bevel (K/F series), worm (NMRV) and planetary gear reducer ranges, plus drop-in equivalents for SEW and NORD units. Send us your motor power, output speed, duty cycle and mounting position for a complete service factor gearbox selection with torque and thermal verification, price and lead time within 24 hours — including free SEW/NORD cross-reference support.