Problems needing attention when using cycloid reducer
Publish Time: 2021-10-29 Origin: WTG
In addition to paying attention to the problems of the product itself, it is also necessary to understand the matters needing attention when using the cycloid reducer, so as to avoid failures caused by improper operation during use.
In order to replace the lubricating oil, the user should determine the amount of lubricating oil according to the size of the reducer type.There are specific regulations, and the specific operation should be in accordance with the operating instructions of the reducer.If the reducer is put into operation in an environment with harsh environment, high temperature and large dust, please check and replace the lubricating oil every 12 months.
When using the reducer, replace the plug on the top of the reducer with the exhaust plug.The purpose of replacing the exhaust plug is to ensure that the reducer removes the gas generated in the reducer during operation.Otherwise, in the case of long-term operation of the reducer, the gas in the reducer will adhere to it, and the longer the operation time, the gas will be added, and then the temperature will rise, causing expansion and damage to the oil seal of the reducer, resulting in Reducer oil leakage.
Since the output shaft structure of the reducer cannot accept the axial hammer, the screw can be screwed into the screw hole of the shaft end to press into the joint.