Step One: Emergency Risk Control (1 minute to complete)
If resonance is accompanied by vibration speed > 6.3mm/s, oil temperature > 90°C, bearing temperature > 95°C, or continuous metal impact sound occurs, stop the machine immediately and lock out and tag out to prevent vicious failures such as broken teeth and bearing lock-up under high torque conditions.
If the working conditions do not allow direct shutdown, fine-tune the inverter parameters immediately to allow the speed to jump out of the narrow range of resonance locking. Cut off the resonance excitation source first to avoid continuous impact damage to components.
Step 2: Rapid vibration reduction on site (completed within 30 minutes, no need to disassemble the machine)
In view of the heavy-load characteristics of the DCY355 large model, external factors accounting for more than 80% are given priority to quickly suppress resonance:
1. Full torque complex fasteners
Use a torque wrench to retighten all M30 specification anchor bolts in diagonal order. The pretightening force of 8.8-level bolts is not less than 350N·m. Retighten the coupling connecting bolts and box flange bolts simultaneously to completely eliminate the problem of insufficient rigidity caused by loosening under heavy load.
2. High-precision correction of shaft system alignment
Use a laser alignment instrument to adjust the coaxiality of the motor-reducer-load, control the radial deviation ≤ 0.05mm, and the angular deviation ≤ 0.1°/m to eliminate the additional excitation force caused by misalignment under high torque conditions.
3. Quickly change the natural frequency of the system
Install an 8~12mm thick rubber shock-absorbing pad with a Shore hardness of 65~75° on the base of the reducer, or weld a 30~50kg counterweight block on the base to directly change the natural frequency of the whole machine and avoid the overlap range with the operating frequency.
4. Optimize coupling buffering performance
Replace the aged and damaged polyurethane elastic pads, eliminate the coupling gap (control gap ≤ 0.3mm), use elastic elements to absorb the resonance impact, and cut off the vibration transmission path to the load side.
Step 3: Root cause cure (completely avoid recurrence of resonance)
After rapid vibration reduction, thorough rectification is made to the causes of insufficient deep rigidity of large models to eliminate potential resonance hazards from the root:
1. Foundation rigidity strengthening: If the steel structure base is not rigid enough, add transverse reinforcing bars (spacing ≤ 600mm); the concrete foundation uses high-strength non-shrinkage grouting material for secondary grouting, and the anchor bolts are equipped with double-nut anti-loosening locking devices to completely eliminate the problem of suspended foundation and insufficient rigidity.
2. Enhancing box damping: Paste an 8~10mm thick high-damping constraint plate on the reducer casing to significantly increase the damping of the box structure, consume resonance energy, and suppress the low-frequency resonance whine unique to large models.
3. Accurate spectrum vibration avoidance: The natural frequency of the whole machine is accurately measured through a vibration spectrum analyzer, and the speed jump range is set in the frequency converter to allow the equipment to completely avoid the resonance speed range and prevent resonance triggering from the control level.
4. Verification of internal transmission parts: Open the cover and check the gear meshing backlash (helical gears are controlled at 0.15~0.4mm) and bearing clearance. If there is pitting and spalling on the tooth surface or the bearing clearance exceeds the standard, repair or replace it in time to eliminate internal abnormal vibration sources.