Analysis of common faults of geared motors

Publish Time: 2021-10-12     Origin: 威高传动

1. The reducer is overheated
1) Insufficient or excessive lubricating oil, oil and oil star exhaust caps are not loosened according to the product instruction manual
2) Cycloidal pinwheel reducer overcurrent protection or load overload, check the cause of the overload of the reducer motor, adjust to meet the requirements or replace the high-power reducer motor
3) Before starting up, confirm the installation direction and open the ventilation cover to exhaust and dissipate heat
4) Different installation methods have different lubricating oil stars.After confirmation, fill up the specified oil star to ensure the lubrication effect and heat dissipation effect
2. The abnormal noise of the geared motor
1) Spin noise.
2) Knocking sound and irregular meshing.
3) When there are impurities in the lubricating oil or the amount of oil is insufficient
Replace lubricating oil or refuel to specified value
3. When the motor rotates, the output shaft of the reducer does not rotate
The key connection of the reducer is damaged or the transmission gear is worn,
Disassemble the machine for repairs and replace parts.
4. Oil spill
1) Adjust the oil level and quantity of lubricating oil;
2) The vent cap is not installed correctly.
Confirm the position and direction of the breather cap to ensure that the breather cap is above or above the lubricating oil;
3) When the oil seal or gland leaks oil, the oil seal or gland is aged or installed incorrectly, replace the oil seal or gland;
4) Replace the gasket or O-ring when the gasket is damaged or aging.


The power supply voltage is too high, resulting in the oversaturation of the magnetic flux density of the iron core, resulting in an excessive temperature rise of the geared motor.Handling suggestion: If the power supply voltage seriously exceeds the standard, please contact the power supply department to solve it.
The power supply voltage is too low, and the temperature rise of the motor is too high under rated load.Handling suggestions: If the voltage drop of the power line is too large, replace the thicker power line; if the power supply voltage is too low, please contact the power supply department to increase the power supply voltage.
When the wire is removed, the iron core will be burned and the iron consumption will be increased.Suggestions for handling: check and test the iron core, repair the iron core, and troubleshoot.
The stator core and the rotor core rub against each other.Handling suggestion: Check the cause of the fault.If the bearing clearance exceeds the limit, replace the bearing.If the rotating shaft is bent, straighten it; when the iron core is loose or deformed, the iron core should be processed to eliminate the fault;

FEEDBACK

What are the maintenance points for ZDY250-3.55-II hard tooth surface reducer in food plants?

How to perform daily inspection of the sealing system of ZDY315-4.5-I hardened reducer?

What is the clearance standard of P series planetary reducer under different working conditions?

How to choose the P series planetary reducer suitable for your equipment

How to detect early fracture of ZLYJ173 reducer gear