What information should be included in the records of regular inspections of bearing temperature of TY125 hardened reducer?

Publish Time: 2026-03-12     Origin: Site

The regular inspection records of bearing temperature of TY125 hard tooth surface reducer should contain the following key information to ensure that the operating status of the equipment can be traced, abnormalities can be warned early, and maintenance can be based on:

1. Basic equipment and environmental information

‌Equipment model‌ : TY125 hard tooth surface reducer

‌Installation location‌ : Such as 'Production Line 3 of Main Transmission Workshop'

‌Check date and time‌ : Accurate to the minute for easy trend analysis

‌Ambient Temperature‌ : Record the ambient temperature (such as 25℃) during measurement, used to calculate temperature rise

‌Operating conditions‌ : Load status (no load/25%/50%/75%/full load), continuous operating time

2. Temperature monitoring core data

‌Measuring point location‌ : clearly marked as the bearing end cover of the input shaft, output shaft or intermediate shaft

‌Actual temperature value‌ : Use an infrared thermometer to measure the surface temperature of the bearing outer ring or end cover

‌Maximum allowable temperature‌ : generally not exceeding 80℃

‌Temperature rise‌ : It is recommended to control it within 40℃

‌Historical baseline comparison‌ : Compare with the baseline temperature during normal operation of the equipment, the deviation exceeds 15℃

3. Auxiliary status observation items

: Whether it is accompanied by abnormal vibration (can be measured with a simple vibrating pen, double amplitude ≤ 0.05mm)

‌Noise characteristics‌ : Is there any abnormal noise such as metal friction and knocking?

‌Sealing status‌ : Is there any leakage or accumulation of oil stains at the oil seal?

‌Lubrication condition‌ : Whether the oil level is within 1/2 to 2/3 of the oil window, and whether the oil quality is clean and non-emulsified

4. Operation and judgment records

‌Measurement Tools‌ : Such as 'FLUKE 62 Max+ Infrared Thermometer'

‌Measurement method‌ : Vertical alignment, avoiding oil stains and heat sinks

‌Judgment Conclusion‌ : Normal/Warning/Abnormal

‌Processing suggestions‌ : Such as normal operation/observation operation/shutdown processing, measures to be taken and results


FEEDBACK

What are the differences in the installation methods of ZSY reducer and DCY gear reducer?

What measures should be taken immediately when the WP series worm reducer is overloaded?

What are the early signs of gear burn in TY series reducer?

Which light-load equipment is suitable for ZDY series gear reducer?

What factors need to be considered for the Selection of the BWD15 cycloidal reducer motor overload protection device?