NGW-S52-11-1 How to determine whether the oil temperature is normal during daily operation of the planetary gear reducer

Publish Time: 2025-09-01     Origin: Site

According to the three indicators of 'actual oil temperature + surface temperature + temperature rise rate': the actual oil temperature is ≤95 ℃, the surface temperature is ≤85 ℃, the temperature rise ≤ambient temperature + 40 K; if any exceeds the limit or rises rapidly within 15 minutes, stop the machine and check immediately.

Determination criteria (applicable to NGW-S52-11-1)

  • Upper oil temperature limit: ≤95 ℃ (equilibrium oil temperature).

  • Surface temperature: ≤85 ℃.

  • Temperature rise rate: A warning will be made if it rises rapidly within 15 minutes.

  • Ambient temperature: -40~40 ℃; preheat or use low condensed oil when <0 ℃.

Daily judgment steps (can be directly executed)

  1. Measure oil temperature: After shutdown for ≥10 minutes, insert the rod thermometer from the dipstick/sampling port for ≥2 minutes to read; during operation, the fixed temperature measurement point close to the oil tank shall prevail.

  1. Review surface: Use an infrared thermometer to measure the middle part of the housing or bearing seat, ≤85 ℃; when the oil temperature is ≥85 ℃ and the oil temperature is close to 95 ℃, stop the machine immediately.

  2. Calculate temperature rise: Temperature rise = actual measured oil temperature - ambient temperature; if it rises rapidly within > 40 K or within 15 minutes, reduce the load first or shut down the machine for inspection.

  3. Synchronous observation: abnormal noise, vibration, oil level/oil quality, sealing and centering; priority is given to check lubrication and installation in case of abnormalities.

Key points and precautions

  • The reading position is consistent with the timing to form a baseline; record 'Oil temperature/surface temperature/ambient temperature/working conditions/time'.

  • Strengthen ventilation and sealing in high-temperature or high-dust environments; in summer, the surface temperature can be set to be a warning of ≥80 ℃.

  • If otherwise specified in the instructions, the manufacturer's parameters shall prevail.


FEEDBACK

What factors need to be considered for the Selection of the BWD15 cycloidal reducer motor overload protection device?

What is the working principle of the overload protection device of BWD27 cycloid reducer?

Failure warning technology of rice mill reducer: realizing preventive maintenance

Lightweight design and convenient maintenance of small rice mill reducer

The decisive influence of the backlash of the cutting machine reducer on the straightness of plate cutting