How to obtain the service coefficient of the reducer: working condition classification, value table and common misjudgments - Hangzhou Weigao Transmission
Publish Time: 2026-10-20 Origin: Site
What is the service coefficient of the reducer: definition and calculation formula
The service factor of the reducer (Service Factor, corresponding application coefficient KA in ISO 6336) is a multiple used to measure 'how much more the rated capacity is than the actual demand' in Selection. The calculation formula is: SF = rated torque of the reducer ÷ working condition demand torque. The reason for its existence is very straightforward: the instantaneous torque of the motor can reach 200% to 300% of the rated value when the motor is started directly. The belt is fully loaded and the material is jammed in the silo, which will cause short-term impacts. The tooth surface contact fatigue accumulates with the 6th power of the peak torque, and the bending fatigue accumulates with the 8th power. The consumption of short-term peaks on the life span far exceeds its proportion of time. A reducer selected based on SF=1.0 does not have any margin, and tooth surface pitting, excessive oil temperature, and oil seal leakage often occur before the design life is used.
When actually checking, first calculate the required torque T = 9550 × P÷n (T is in N·m, P is in kW, and n is in r/min), then multiply it by the service coefficient to get the Selection torque. Use the Selection torque calculated by the reducer { [t12]} to compare it with the sample rating, instead of directly applying the motor nameplate power.
Load classification and basic value table
According to the ideas of AGMA 2101/6013 and ISO 6336-1, the load is divided into three categories according to the nature of the impact. The corresponding basic value of the service factor of the reducer is as follows (based on motor drive and daily operation of ≤10 hours):
Load properties |
Typical equipment |
SF (≤10h/day) |
SF (24h continuous) |
|---|---|---|---|
uniform load |
Centrifugal pump, fan, light load stable transportation |
1.00~1.25 |
1.25 |
medium impact |
Loaded conveyors, mixers, packaging machinery, machine tool feed |
1.25~1.50 |
1.50~2.00 |
Heavy load shock |
Crusher, press, reversible rolling mill, frequent forward and reverse equipment |
1.75~2.50 |
2.50~3.00 |
For the same conveyor reducer , 1.0~1.25 is used for uniform feeding. For large material fluctuations or full load startup, 1.5 should be used for medium impact. Equipment such as bucket elevators and plate feeders that start with materials generally take 1.5 or more. It should be noted that the sample standards of each manufacturer are not completely consistent. Some samples set the uniform load standard as 1.25. The sample instructions should be checked before taking the value.
Three corrections: duration, starting method and prime mover
There are three types of corrections after the basic value, and many Selection mistakes occur here:
1. Operation time: Add about 0.25 for more than 10 hours per day. For 24-hour continuous operation, take the value as listed in the table - heat accumulation under continuous working conditions must be verified separately with the thermal power check of the reducer . Sufficient mechanical power does not mean that the thermal power is sufficient; 2. Starting method: direct full-voltage start (without soft starter/inverter), add about 0.25, and add 0.25~0.5 for scenarios with more than 10 starts and stops per hour; 3. Prime mover: Diesel engine and internal combustion engine drive add about 0.2 to the electric motor drive, and the reciprocating prime mover with obvious pulsation is even higher.
When multiple factors are superimposed, they should be multiplied item by item to obtain the comprehensive coefficient. For example, under transportation conditions of 16 hours of operation, 8 starts and stops per hour, and an ambient temperature of 45°C, the comprehensive service factor may reach about 2.3, which is more than 60% higher than simply looking at a table. This is the difference between "selecting based on the table will cause failure in one year, but based on comprehensive calculation, it will last for many years."
Two common misjudgments: SF is not overload capability, and don’t just focus on mechanical power.
Misjudgment 1: Treat the service factor as the overload multiple. SF=2.0 means that Selection leaves twice the design margin, which does not mean that the reducer can withstand 200% overload operation for a long time; the allowable short-term peak value depends on the allowable impact torque of the sample (usually 2 to 3 times the rated value), and the two are two calibers.
Misjudgment 2: Only calculate mechanical power and ignore heat. The large speed ratio, small machine base, and worm gear structure generate a lot of heat under continuous working conditions. A considerable part of the cause of reducer heating is insufficient thermal power rather than insufficient gear strength. At this time, the frame size should be enlarged or a higher-efficiency hardened surface reducer should be selected instead of continuing to increase the service factor. When checking the matching of motor power and reducer , mechanical check, thermal check and peak impact check must be passed.
Selection Check the five-step checklist
1. Confirm the load properties and daily operating hours, and determine the basic SF from the value table; 2. Overlay the duration, starting frequency, prime mover and ambient temperature one by one; 3. Selection Torque = demand torque × comprehensive SF, and compare the rated torque of the sample to the nearest one; 4. Check the thermal power and allowable peak torque (the starting/braking moment does not exceed the sample impact limit); 5. Review the cantilever load and radial force of the output shaft. The cantilever load cannot be omitted when the sprocket and pulley are driven.
If you are for conveying, mixing, lifting or crushing equipment consulting on reducers , please contact Hangzhou Weigao Transmission - as a reducer manufacturer, we provide a complete product line of cycloidal pinwheel reducers, hard tooth surface gear reducers, worm gear reducers and gear reduction motors. The technical team can perform free service coefficient and thermal power verification according to your working conditions, and provide solutions and quotations from local reducer manufacturers in Hangzhou.