How to judge the cause of reducer heating: temperature rise limit, temperature measurement method and alarm value setting-Hangzhou Weigao Transmission

Publish Time: 2026-10-20     Origin: Site

How to judge the cause of reducer heating: first look at the limit value and then talk about the fault

When the reducer is 'hot to the touch' on site, many people's first reaction is that it is broken. In fact, to judge the cause of the heat of the reducer , you must first check the temperature limit instead of relying on the feel. It is a common phenomenon for cast iron or aluminum alloy casings to reach 60~80°C during continuous operation. Hands cannot touch them for a long time. However, as long as the temperature is stable after thermal equilibrium and the temperature rise does not exceed the limit, the equipment may not be faulty. The judgment framework given by the industry's common reference values ​​(such as JB/T 8853 and samples from various manufacturers) is: oil pool temperature, bearing temperature, shell temperature and temperature rise (ΔT, temperature difference with the environment). The four indicators are compared separately. The temperature rise is more worthy of attention than the absolute temperature - the shell is 85°C when the environment is 40°C and the shell is 85°C when the environment is 10°C. The meanings are completely different.

Comparison table of temperature limits for housing, oil sump and bearings

Based on mineral oil lubrication and ambient temperature of about 25°C, the temperature reference of each part of the general gear reducer is as follows:

Measurement part

normal range

Alarm value

shutdown value

shell surface

40~80℃

80~90℃

≥90℃

Oil pool temperature

40~75℃

80~85℃

≥90℃

Bearing parts

≤80℃

85~90℃

≥95℃

Temperature rise (difference from ambient temperature)

≤45℃

45~50℃

≥50℃

When the oil temperature exceeds 80°C for a long time, the oxidation of mineral oil is significantly accelerated, the viscosity decreases, and the oil film becomes thinner. When the oil temperature exceeds 90°C, the additives are rapidly consumed. Above 100°C, coking and carbon deposits will occur and the oil circuit will be blocked, eventually leading to tooth surface gluing and bearing burnout. Therefore, the oil pool alarm value is generally set at 80~85℃, and the shutdown value is 90℃; the bearing alarm value is 90℃, and the shutdown value is 95℃. After exceeding the value, the cage and raceway will temper and soften.

Differences in limits between worm gear reducers and hard tooth surface reducers

The allowable temperatures of different models are not the same. Worm gear reducers are mainly based on sliding friction, have low efficiency, and generate large amounts of heat. However, the bronze rim of the worm gear is more sensitive to temperature, and the limit value should be 5~10°C lower than that of the gear reducer: the shell and oil temperature should not exceed 70°C for a long time. Exceeding 75°C for a long time will easily cause the worm gear tooth surface to soften and increase wear. The temperature rise should be controlled within 40°C. The carburized and quenched tooth surface of the hard-tooth surface reducer has strong resistance to gluing. The oil pool can reach 85°C in a short time, but the risk of gluing increases significantly when it exceeds 85°C for a long time. Precision planetary models are the most sensitive to temperature. If the oil temperature exceeds 80°C, you should be wary of increased backlash and loss of accuracy.

Classification of reducer heating causes : Check the heat generating side and heat dissipating side one by one

After confirming the over-temperature, it is more efficient to check according to the "heat generation" and "heat dissipation" lines than to replace parts one by one:

Heat-generating side: 1. Poor lubrication - the oil level is too low, the oil type is wrong or the oil is emulsified . The reducer lubricating oil model should be selected according to the sample viscosity range (common VG220/VG320/VG460), and the worm gear model should use special oil according to the manufacturer's requirements; 2. Overload - the entire shell is heated and the motor current is synchronously high. First eliminate transportation obstructions and changes in the viscosity of the stirring material; 3. Alignment deviation - the bearing end cover on one side is locally overheated and accompanied by vibration, re-test the coupling coaxiality; 4. Part wear - local high temperature and 'sand' friction sound, check the tooth surface for pitting corrosion and the bearing raceway.

Heat dissipation side: The ambient temperature exceeds 40°C, too much oil is added (oil churning loss increases), the heat dissipation ribs are covered with dust and sludge, and the continuous operation of a small machine base with a large speed ratio causes the thermal power check of the reducer to fail. For overtemperature caused by insufficient heat dissipation, the solution is to improve ventilation, clean the casing, install a cooling fan or enlarge the base, rather than continue to increase the alarm value.

Temperature measurement method and measurement point layout

Three combinations of methods are recommended for on-site temperature measurement: measuring the shell with an infrared thermometer (set the emissivity to 0.95, and the measuring distance is about 1.5 times the diameter of the measuring point, and wipe off the oil before measuring, otherwise the error can reach 10°C); PT100 platinum resistor patch or threaded probe to monitor the bearing seat and oil pool (immersed in the oil pool for more than 50mm, away from the tank wall and oil return port, and the 4~20mA signal is connected to the PLC); the thermal imager scans the entire unit to find local hot spots. The measuring points should be arranged at least three places: the input/output shaft bearing seat, the middle of the housing, and near the oil level window. Two practical trend criteria: the temperature of the bearing end cover is more than 15°C higher than the shell, indicating that the bearing has a local failure; under the same working condition, the temperature suddenly increases by more than 10°C compared with the historical record, or the temperature rise rate exceeds 1°C/min and continues to rise. Even if the limit value is not exceeded, the machine should be shut down for investigation.

Alarm value setting and daily maintenance points

It is recommended that the threshold of the PLC or online monitoring system be set according to the principle of 'set alarm at +10~15°C and set shutdown at +5°C'. For example, equipment with a normal oil temperature of 65°C should set an alarm at 80°C and shut down at 90°C, and record the temperature-time curve for trend management. Routine reducer maintenance : Check the oil level and shell temperature every shift and record them. The oil change cycle is carried out according to the instructions. When changing the oil, check that the oil model matches the ambient temperature. Clean the cooling ribs and fans before high-temperature seasons and check whether the ventilation plug is clogged. A clogged ventilation plug will cause the internal pressure of the box to rise. It is not only a common cause of oil leakage, but also indirectly increases the oil temperature.

If your equipment repeatedly over-temperatures, or your new project requires a complete reducer consultation (including three verifications of mechanical power, thermal power and peak impact), please contact Hangzhou Weigao Transmission - as a reducer manufacturer, we provide a complete product line of cycloidal pinwheel reducers, hardened surface gear reducers, worm gear reducers and gear reduction motors. The technical team of local reducer manufacturers in Hangzhou can provide free solutions and quotations according to your working conditions.

FEEDBACK

Offshore Wind Vessel Gearbox Market 2027: Crane and Winch Drive Demand

How to check the carrying capacity of worm gear reducer: working condition coefficient, efficiency and Selection calculation example - Hangzhou Weigao Transmission

Lubrication and maintenance characteristics of B series industrial gearboxes

What are the common misunderstandings in B series gearbox maintenance?

Apron Feeder Gearbox Selection: Chain Pull, Shock Load and Service Factor