Gearbox Duty Cycle Selection: S2/S4/S6 Ratings and What They Mean for Gear Motors
Publish Time: 2026-10-24 Origin: Site
Most gear motor failures blamed on quality are really selection errors, and they start with a question the order form rarely asks: what duty does this drive actually run? Gearbox duty cycle selection converts an operating pattern — load, run time, rest time, starts per hour — into a thermal and mechanical rating. Skip it and a unit rated for continuous service ends up on a hoist that starts 200 times an hour.
IEC 60034-1 defines ten duty types, S1 to S10, and most industrial gear motors are ordered under S2, S4 or S6. Read correctly, those codes state how much torque the drive may carry, how often it may start, and whether the oil sump recovers between cycles.
What the S-Codes on a Nameplate Mean
A duty code is a thermal statement: it describes how winding and lubricant behave over time, which is why one frame carries different ratings per code.
Duty | Behaviour | Typical drive |
|---|---|---|
S1 | Constant load, equilibrium reached | Pump, fan, 24/7 conveyor |
S2 30 min | Load, then rest to within 2 K of ambient | Sluice gate, valve |
S4 25% | Start, run, rest; starting heat counted | Hoist, frequent-start conveyor |
S6 40% | Load and no-load, never de-energised | Mill table, kiln auxiliary |
For S3 to S5 the cyclic duration factor is quoted against a 10-minute reference cycle: 15%, 25%, 40% or 60%. S2 states a duration instead — 10, 30, 60 or 90 minutes. An unmarked nameplate defaults to S1.
The Four Inputs Behind Gearbox Duty Cycle Selection
Four numbers do the real work. The cyclic duration factor is loaded time divided by cycle time. Starts per hour matter because each start delivers a torque pulse well above running torque. The inertia ratio between load and motor sets how long acceleration lasts. The load spectrum decides whether peak or average torque governs.
The codes carry these inputs directly. A nameplate reading "S4 25% JM = 0.15 kgm² Jext = 0.7 kgm²" gives the cyclic duration factor plus both inertias at the motor shaft.
From Duty Class to Service Factor
Crane work follows FEM 9.511, M1 to M8, mapping roughly onto ISO 4301 groups A1 to A8; industrial drives follow AGMA 6010.
Classification | Service factor | Example |
|---|---|---|
FEM M3–M4 / AGMA Class I | 1.25–1.4 | Light travel drive |
FEM M5–M6 / AGMA Class II | 1.5–1.6 | Production hoist, mixer |
FEM M7–M8 / AGMA Class III | 1.75–2.0 | Ladle crane, crusher |
Two adjustments get forgotten: 24-hour operation adds about 0.25 to the AGMA figure, reversing duty about 0.5. The multiplier is not cosmetic — pitting life scales with service factor to roughly the 8.8 power, so 1.0 to 1.3 multiplies tooth life by about ten.
Thermal Rating and What a Rest Period Buys You
Intermittent duty helps because heat leaves the housing whenever the drive stops. A 7.5 kW unit at 96% efficiency loses about 300 W. A ribbed cast-iron housing of 1.2 m² with a convection coefficient near 10 W/m²K sheds some 480 W at a 40 K oil-to-air difference — comfortable at 40°C ambient, marginal at 55°C, where a shaft fan becomes mandatory.
So gearbox thermal power rating has to be checked against the duty cycle, not just the torque table. A 40% cyclic duration factor leaves the sump recovering for most of each cycle; an S6 drive never stops to recover.
Worked Example: An S4 Travel Drive
A travel drive on a 90-second cycle: 30 s loaded at 100 N·m, 30 s return at 40 N·m, 30 s at rest. Equivalent torque over running time is √((100²×30 + 40²×30)/60) = 76 N·m. Weighting rest at half cooling gives √(348,000/75) = 68 N·m — what the gearbox must survive thermally.
With the M5 factor of 1.5 the required output rating becomes 102 N·m. On a 30-tonne hoist at 60:1 and 92% efficiency, 22,242 N·m at the drum needs 403 N·m at the input shaft, 604 N·m after the factor. Selecting on the running figure alone undersizes the unit by a third.
Three Mistakes in Gearbox Duty Cycle Selection
Assuming S1 by default on a machine that stops and starts constantly — safe for motors, wrong for a gearbox with a high start count.
Counting only running hours and ignoring starts per hour, which carry far more fatigue damage.
Applying motor duty data to the gearbox — S-codes describe winding limits, while gear capacity follows service factor.
Getting the Duty Right Before the Order
Log a week of cycles, count starts, note loaded versus idle time, and put the result on the enquiry. A correctly coded drive needs no derating later; a mis-coded one cannot be rescued by a bigger oil cooler.
WGT builds helical, bevel-helical, planetary and worm gear units with duty and thermal data published per frame size, plus the cooling options intermittent duty often demands. Our units are dimensionally interchangeable with SEW and NORD ranges, so an existing drive can be re-rated for its real duty cycle without redrawing the baseplate. Send your cycle profile — loaded torque, run and rest times, starts per hour, ambient — and our engineers will confirm the duty class, service factor and thermal margin that gearbox duty cycle selection turns on before you commit to a frame size.